Industrial & machine: family overview
3 classes from machines: CAN bus signals, PLC tags and motor drive or spindle telemetry.
Overview
Industrial & machine has 3 classes: CAN / CAN-FD bus signals, PLC tags (Modbus, OPC-UA) and motor drive / spindle telemetry. Two of the three are already digital: the machine has done the sensing and publishes values, so what matters is the bus and the scan cycle. Motor-drive telemetry still carries real physics: phase currents, spindle torque and vibration.
3 classes · 1 circuit card · Requirements grid for this family
What it senses
- Machine state published as values on a bus.
- Phase currents, torque and vibration of drives.
Modalities in this family
3 classes, grouped by physics. Open the requirements grid for bandwidth, data rate, link tier and the other views.
Digital, timing and derived 2
- CAN / CAN-FD bus signalsPrototypedcard 25
- PLC tags (Modbus, OPC-UA)Possible
Composite or multi-physics 1
- Motor drive / spindle telemetryPossiblecard 25
Key physics
- Flux and conjugate pair: Bus classes: differential V·I on a transmission line carrying bits, with no sensed flux; drives: electrical V·I, mechanical τ·ω at the spindle and vibration F·v.
- Characteristic scale: CAN twisted pair Z0 ≈ 120 Ω, CAN-FD to ~5–8 Mb/s, ~40 m at 1 Mb/s; Ethernet 100 Ω differential, RS-485 120 Ω; drive PWM ~4–16 kHz (typ.).
- Resonance / aperture condition: Terminate both bus ends at the line impedance so the signal propagates without reflections, and keep stubs short; drive current sensors need bandwidth above the PWM harmonics, and mechanical resonance limits what is observable.
In the shared space: the hypothesis is that bus values enter the ring as already-labelled time series (an embedding plus a scan-cycle timestamp), while drive telemetry can be mapped alongside the vibration and power classes. Not measured.
Strengths and limits
Strengths
- The machine has already done the sensing, so the value is clean and cheap to read.
- Scan cycles are regular, which helps alignment.
Limits
- The bus and scan cycle, not the physics, limit what is available.
- Protocol access and write safety need care.
Front-end circuits
- 25 CAN bus node: transceiver, termination and timestamping serves: CAN / CAN-FD bus signals; Motor drive / spindle telemetry
Open questions for the symposium
- How are bus time stamps related to the symposium time base?
- Which machine signals are trustworthy enough to count as ground truth?
Symposium room. Planned room: IND. See the plan and the run of show. Room sessions are marked Coming; no results exist yet.
Update log
- v3 Family page created with overview, modalities, physics, strengths and limits, open questions and this log.