Bio & wearables: family overview
4 classes on or near the body: biopotential, optical pulse, EMG and EEG, and the phone or glasses bundle.
Overview
Bio & wearables has 4 classes on or near the body: ECG / biopotential, PPG / SpO2 / skin temperature, EMG / EEG, and the smart glasses / phone sensor bundle. They differ from room sensing because the sensor touches the subject: coupling to skin, not a radiating aperture, decides what is measured. The bundle is a device, not a physics, and is split into its component classes.
4 classes · 2 circuit cards · Requirements grid for this family
What it senses
- Heart and muscle electrical activity.
- Pulse, oxygen saturation and skin temperature.
- Brain signals, and the sensors of a worn device.
Modalities in this family
4 classes, grouped by physics. Open the requirements grid for bandwidth, data rate, link tier and the other views.
Optical / infrared photons 1
- PPG / SpO2 / skin tempPossiblecard 21
Composite or multi-physics 1
- Smart glasses / phone sensor bundleIdentified
Key physics
- Flux and conjugate pair: Biopotentials: V·I, where ion currents in tissue are transduced to electron current at the electrode; PPG: photon flux through tissue, absorbed by haemoglobin (Beer–Lambert).
- Characteristic scale: Skin–electrode impedance kΩ–MΩ; ECG band ~0.05–150 Hz; EMG ~20–500 Hz up to ~mV, EEG ~0.5–100 Hz at ~µV; PPG at 525–560, 660 and 940 nm with a pulsatile part ~1 % of DC (typ.).
- Resonance / aperture condition: High input impedance (≥ 100 MΩ) and CMRR (> 100 dB, typ.) with a driven right leg make the electrode a quasi-static “antenna”; for PPG the LED–photodiode spacing sets penetration depth.
In the shared space: the hypothesis is that the device bundle is a natural place to test map fitting, since its parts see the same subject at the same moment; the shared clock, battery and mount are also common causes that can fake agreement. Not measured.
Strengths and limits
Strengths
- Direct physiological signal that room-scale sensing can only infer.
- Compact front ends with well-known circuits.
Limits
- Coupling to the skin decides what is measured, not a radiating aperture.
- The device bundle is not one physics and must be split into its components.
Front-end circuits
- 20 ECG biopotential front end serves: ECG / biopotential; EMG / EEG
- 21 PPG and SpO2 optical front end serves: PPG / SpO2 / skin temp
Open questions for the symposium
- Can a body-worn signal anchor a room-scale radar or CSI estimate?
- What consent and privacy rules apply before body signals enter a shared dataset?
Symposium room. Planned room: BIO. See the plan and the run of show. Room sessions are marked Coming; no results exist yet.
Update log
- v3 Family page created with overview, modalities, physics, strengths and limits, open questions and this log.