Omni Modal Sensor Symposium

Industrial & machine

Industrial & machine: 3 stream classes, with eight grid views.

Industrial & machine: physics in brief

Industrial & machine has 3 classes: CAN / CAN-FD bus signals, PLC tags (Modbus, OPC-UA) and motor drive / spindle telemetry. Two of the three are already digital: the machine has done the sensing and publishes values, so what matters is the bus and the scan cycle. Motor-drive telemetry still carries real physics: phase currents, spindle torque and vibration.

  • Flux and conjugate pair: Bus classes: differential V·I on a transmission line carrying bits, with no sensed flux; drives: electrical V·I, mechanical τ·ω at the spindle and vibration F·v.
  • Characteristic scale: CAN twisted pair Z0 ≈ 120 Ω, CAN-FD to ~5–8 Mb/s, ~40 m at 1 Mb/s; Ethernet 100 Ω differential, RS-485 120 Ω; drive PWM ~4–16 kHz (typ.).
  • Resonance / aperture condition: Terminate both bus ends at the line impedance so the signal propagates without reflections, and keep stubs short; drive current sensors need bandwidth above the PWM harmonics, and mechanical resonance limits what is observable.

In the shared space: the hypothesis is that bus values enter the ring as already-labelled time series (an embedding plus a scan-cycle timestamp), while drive telemetry can be mapped alongside the vibration and power classes. Not measured.

Impedance analogies: one series loop drawn four ways Four panels show the same series loop with a source, a resistance, an inertance and a capacitance. Electrical: V, R, L, C, current I. Acoustic: pressure p, acoustic resistance, acoustic mass (like inductance), compliance (like capacitance), volume velocity U (like current). Mechanical, impedance analogy: force F like voltage, velocity v like current, mass like inductance, compliance 1/k like capacitance, damping like resistance. Thermal: temperature difference like voltage, heat flow like current, thermal resistance and heat capacity only, no inductance, so it is diffusive and never resonates. Dots on the bottom wire show the flow: oscillating in the first three, decaying one way in the thermal loop. Electrical Z = R + jωL + 1/(jωC) V R L C I (current) effort: voltage V flow: current I inertance: inductance L storage: capacitance C loss: resistance R resonance ω0 = 1/√(LC) Acoustic (impedance analogy) Za = p/U (Pa·s/m³); p·U in W p Ra Ma Ca U (volume velocity) pressure p ↔ voltage V volume velocity U ↔ current I acoustic mass Ma ↔ inductance L compliance Ca ↔ capacitance C acoustic resistance Ra ↔ R ω0 = 1/√(MaCa) (Helmholtz) Mechanical (impedance analogy) Zm = F/v (N·s/m); F·v in W F Rm m 1/k v (velocity) force F ↔ voltage V velocity v ↔ current I mass m ↔ inductance L compliance 1/k ↔ capacitance C damping Rm ↔ R ω0 = √(k/m) Thermal diffusive: RC only, no resonance ΔT Rth (no inductor) Cth q (heat flow, W) temperature ΔT ↔ voltage V heat flow q ↔ current I heat capacity Cth ↔ C thermal resistance Rth ↔ R no thermal inductance: τ = Rth·Cth, decays, never rings
The same lumped network in four domains (impedance analogy).

Front-end circuits for this family

Industrial & machine: requirements grid (3 classes)

3 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.

Overview

ClassFamily / bandRateBandwidthLink tierMaturityProvenance
CAN / CAN-FD bus signalsIndustrial & machine100-10k frames/s10-500 kB/sField busprototypedrepo
PLC tags (Modbus, OPC-UA)Industrial & machine0.1-100 HzkB/s per PLCEthernet 1Gpossibletypical
Motor drive / spindle telemetryIndustrial & machine1 Hz-10 kHzkB-MB/sEthernet 1Gpossibletypical

Timing & bandwidth

ClassFamily / bandExamplesRateBandwidthTierLatencyJitterSync
CAN / CAN-FD bus signalsIndustrial & machinecan-fd, can-anomaly cogs (plan P7)100-10k frames/s10-500 kB/sT2 10 kB-1 MB/smsmsno time in CAN payload
PLC tags (Modbus, OPC-UA)Industrial & machinenone yet0.1-100 HzkB/s per PLCT1 10 B-10 kB/s10 ms-smsPTP/NTP
Motor drive / spindle telemetryIndustrial & machinenone yet1 Hz-10 kHzkB-MB/sT2 10 kB-1 MB/smsµsµs (EtherCAT DC)

Compute & storage

ClassComputeCan run onMemoryStoragePower
CAN / CAN-FD bus signalsdecode, anomalyMCU, SBCKBdecoded signalsself
PLC tags (Modbus, OPC-UA)noneedge gatewayKBhistoriann/a
Motor drive / spindle telemetryedge MLedgeMBsfeaturesn/a

Link & mesh

ClassTransportLink tierReachUnitMesh status
CAN / CAN-FD bus signalsCANField busreachable nowsource+processorschema + vectors
PLC tags (Modbus, OPC-UA)EthernetEthernet 1Gneeds new linksourcenothing yet
Motor drive / spindle telemetryEtherCAT, PROFINETEthernet 1Gneeds new linksourcenothing yet

Physics & health

ClassEnv. sensitivityCalibrationFailure signatureCross-checkCommon causeEM-acoustic crossover
CAN / CAN-FD bus signalsEMIDBC filesbus-off, error framesphysical sensorsbusnone identified
PLC tags (Modbus, OPC-UA)nonetag mapstale tagsphysical sensorsPLCnone identified
Motor drive / spindle telemetryloadcommissioningalarmsvibration, currentdrivemotor current, vibration and magnetic field; partners ac7, im2

Physics & flux

Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).

ClassPhysics groupConjugate pair / energy fluxCharacteristic scaleResonance / aperture ("antenna") conditionShared-space hook (rotation, scale, phase gate)
CAN / CAN-FD bus signalsDIG Digital, timing and deriveddifferential V·I on a transmission line; frames carry bitstwisted pair Z0 ≈ 120 Ω; CAN-FD to 5–8 Mb/s; ~40 m at 1 Mb/sterminate both ends with 120 Ω (no reflections = real propagating signal); stubs kept short (~0.3 m at 1 Mb/s, typ.)Not a sensing physics. Enters the ring only as an embedding or a time label; its health is the clock and link, not the field.
PLC tags (Modbus, OPC-UA)DIG Digital, timing and derivedbits over Ethernet/serial (V·I on the line)Ethernet 100 Ω differential; Modbus RTU RS-485 120 Ωtermination and cabling; scan-cycle timestamps are the time baseNot a sensing physics. Enters the ring only as an embedding or a time label; its health is the clock and link, not the field.
Motor drive / spindle telemetryMIX Composite or multi-physicselectrical V·I in the drive; mechanical τ·ω at the spindle; vibration F·vdrive PWM 4–16 kHz (typ.); spindle resonancecurrent sensors with bandwidth > PWM harmonics; mechanical resonance limits observable contentSplit into its component modalities before mapping; each part uses its own group.

Scale

ClassRoom x10Building x300Factory x5000Compute at factoryScale note
CAN / CAN-FD bus signals501 kB/s15 MB/s251 MB/szone edge aggregators; ship derived onlysame as building
PLC tags (Modbus, OPC-UA)32 kB/s949 kB/s16 MB/sedge aggregator per floorcore of factory scale
Motor drive / spindle telemetry316 kB/s9.5 MB/s158 MB/szone edge aggregators; ship derived onlysame as building

Governance

ClassMaturityPrivacyProvenance
CAN / CAN-FD bus signalsprototypedlowproject notes: can.frame.v1; ventuno-q-cog-plan P7; copper-bus README (CanTSyn)
PLC tags (Modbus, OPC-UA)possiblelowtypical
Motor drive / spindle telemetrypossiblelowtypical