Power & electrical has 5 classes: current / energy metering (CT, smart meter), power quality / waveform capture at kHz, node / board telemetry (power draw, thermals), EMI / RF emission signatures and battery / BMS state. The family watches both the loads in a space and the sensing nodes themselves, so it is a modality (which equipment is running) and a health input for the rest of the grid.
Flux and conjugate pair: Electrical power P = V·I, with voltage and current as the conjugate pair; CTs use Faraday induction V = −dΦ/dt; EMI adds conducted V·I and radiated S = E × H.
Characteristic scale: Line frequency 50/60 Hz; the 50th harmonic needs sampling above ~6 kHz; shunts in mΩ; EMC bands 150 kHz–6 GHz (λ = 2 km–5 cm).
Resonance / aperture condition: Input matching, isolation and anti-alias filtering with bandwidth ≫ the harmonics; CT core and burden set the passband (a Rogowski coil needs an integrator); EMI near-field probes are ≪ λ and read E or H separately.
In the shared space: the hypothesis is that V·I fits the same conjugate-pair structure as p·v and E·H (the impedance analogy), giving power signals a defined place in the map, while board telemetry acts as a common-cause term rather than a sensed signal. Not measured.
Energy flux and its conjugate pair in EM, acoustic and thermal transport. Thermal transport is diffusive and has no propagating phase.
Symposium rooms. Planned room: PWR. Context pack: PWR. Experts: pwr-physics, pwr-signal. Planned room PWR (2 agents), chaired by pwr-physics; no hot cells; reviewed by the adversarial group in S2.4. Symposium plan (plan only, not launched).
Power & electrical: requirements grid (5 classes)
5 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.
Overview
Class
Family / band
Rate
Bandwidth
Link tier
Maturity
Provenance
Current / energy metering (CT, smart meter)
Power & electrical
1 Hz-1/min
bytes/s
Field bus
possible
typical
Power quality / waveform (kHz)
Power & electrical
1-50 kS/s
10-200 kB/s
Ethernet 1G
possible
typical
Node / board telemetry (power draw, thermals)
Power & electrical
0.1-1 Hz
bytes/s
MCU bus
prototyped
repo
EMI / RF emission signature
Power & electrical (also EM: LF-HF)
MS/s
1-100 MB/s raw
USB
possible
typical
Battery / BMS state
Power & electrical
0.1-1 Hz
bytes/s
Field bus
possible
typical
Timing & bandwidth
Class
Family / band
Examples
Rate
Bandwidth
Tier
Latency
Jitter
Sync
Current / energy metering (CT, smart meter)
Power & electrical
none yet
1 Hz-1/min
bytes/s
T0 trickle
s
s
s
Power quality / waveform (kHz)
Power & electrical
none yet
1-50 kS/s
10-200 kB/s
T2 10 kB-1 MB/s
ms
µs
µs (synchrophasor)
Node / board telemetry (power draw, thermals)
Power & electrical
board-telemetry cog (edge-node plan P0)
0.1-1 Hz
bytes/s
T1 10 B-10 kB/s
s
s
s
EMI / RF emission signature
Power & electrical (also EM: LF-HF)
none yet
MS/s
1-100 MB/s raw
T3 MB/s
s
µs
ms
Battery / BMS state
Power & electrical
none yet
0.1-1 Hz
bytes/s
T0 trickle
s
s
s
Compute & storage
Class
Compute
Can run on
Memory
Storage
Power
Current / energy metering (CT, smart meter)
none
MCU
bytes
years
self
Power quality / waveform (kHz)
FFT
MCU, SBC
MBs
events
self
Node / board telemetry (power draw, thermals)
none
node
bytes
long
none
EMI / RF emission signature
FFT, ML
SBC, GPU
MBs
signatures
W
Battery / BMS state
none
MCU
bytes
long
self
Link & mesh
Class
Transport
Link tier
Reach
Unit
Mesh status
Current / energy metering (CT, smart meter)
Modbus, Wi-Fi
Field bus
reachable now
source
nothing yet
Power quality / waveform (kHz)
Ethernet
Ethernet 1G
needs new link
source+processor
nothing yet
Node / board telemetry (power draw, thermals)
in-node
MCU bus
reachable now
source
schema + vectors
EMI / RF emission signature
USB SDR
USB
reachable now
source+processor
nothing yet
Battery / BMS state
SMBus, CAN
Field bus
reachable now
source
nothing yet
Physics & health
Class
Env. sensitivity
Calibration
Failure signature
Cross-check
Common cause
EM-acoustic crossover
Current / energy metering (CT, smart meter)
none
CT ratio
phase swap
board telemetry
panel
none identified
Power quality / waveform (kHz)
none
reference
clipping
vibration
feeder
transformer and motor hum; partner ac1
Node / board telemetry (power draw, thermals)
none
none
sensor missing
energy meter
node
none identified
EMI / RF emission signature
other emitters
antenna
overload
current
antenna
partial discharge emits RF and ultrasound; partner ac6
Battery / BMS state
temperature
coulomb
SoC drift
current
pack
none identified
Physics & flux
Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).
Class
Physics group
Conjugate pair / energy flux
Characteristic scale
Resonance / aperture ("antenna") condition
Shared-space hook (rotation, scale, phase gate)
Current / energy metering (CT, smart meter)
ELEElectrical power and biopotential
V·I; current transformer: Faraday induction V = −dΦ/dt