Contact & physical has 5 classes that read contact, load and state directly: pressure mat / FSR, load cell / strain gauge, door / reed / limit switch, capacitive proximity / touch, and flow / level / position encoders. They are the simplest sensors in the grid and often the most trusted, because a switch or a load cell leaves little room for interpretation, which makes them useful ground truth for the richer classes.
Flux and conjugate pair: Mostly F·v (force and velocity; stress and strain rate), converted to V·I by a bridge or resistive element; capacitive and reed sensing use quasi-static E or H fields.
Characteristic scale: Contact pressure kPa–MPa; strain-gauge factor ≈ 2 with ~2 mV/V at full scale (typ.); capacitance ~pF with fF changes; reed thresholds ~a few mT (typ.).
Resonance / aperture condition: Quasi-static, so no wave: compliance, electrode or magnet geometry is the aperture; a mechanical resonance f0 = (1/2π)√(k/m) bounds load-cell bandwidth; switches need ~ms debounce.
In the shared space: the hypothesis is that these low-dimensional, near-binary signals act as anchor labels for fitting and checking maps rather than as embeddings to be rotated. Not measured.
The same lumped network in four domains (impedance analogy).
Symposium rooms. Planned room: PHY. Context pack: PHY. Experts: phy-physics, phy-signal. Planned room PHY (2 agents), chaired by phy-physics; hot cells with MATH in S3.1; reviewed by the adversarial group in S2.4. Symposium plan (plan only, not launched).
Contact & physical: requirements grid (5 classes)
5 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.
Overview
Class
Family / band
Rate
Bandwidth
Link tier
Maturity
Provenance
Pressure mat / FSR
Contact & physical
10-100 Hz
<10 kB/s
MCU bus
possible
typical
Load cell / strain gauge
Contact & physical
10 Hz-1 kHz
<10 kB/s
MCU bus
possible
typical
Door / reed / limit switch
Contact & physical
events
bytes
MCU bus
possible
typical
Capacitive proximity / touch
Contact & physical
10-100 Hz
<1 kB/s
MCU bus
prototyped
repo
Flow / level / position encoders
Contact & physical
1 Hz-10 kHz
bytes-kB/s
Field bus
possible
typical
Timing & bandwidth
Class
Family / band
Examples
Rate
Bandwidth
Tier
Latency
Jitter
Sync
Pressure mat / FSR
Contact & physical
none yet
10-100 Hz
<10 kB/s
T1 10 B-10 kB/s
0.1 s
ms
s
Load cell / strain gauge
Contact & physical
none yet
10 Hz-1 kHz
<10 kB/s
T1 10 B-10 kB/s
ms-s
ms
ms
Door / reed / limit switch
Contact & physical
none yet
events
bytes
T0 trickle
ms-s
s
s
Capacitive proximity / touch
Contact & physical
GT911 touch (weftos-leaf-touch-gt911)
10-100 Hz
<1 kB/s
T1 10 B-10 kB/s
10-50 ms
ms
s
Flow / level / position encoders
Contact & physical
none yet
1 Hz-10 kHz
bytes-kB/s
T1 10 B-10 kB/s
ms-s
ms
ms
Compute & storage
Class
Compute
Can run on
Memory
Storage
Power
Pressure mat / FSR
light
MCU
KB
events
mW
Load cell / strain gauge
none
MCU
KB
long
mW
Door / reed / limit switch
none
MCU
bytes
events
uW
Capacitive proximity / touch
none
MCU
bytes
events
mW
Flow / level / position encoders
none
MCU, PLC
bytes
long
mW-W
Link & mesh
Class
Transport
Link tier
Reach
Unit
Mesh status
Pressure mat / FSR
ADC
MCU bus
reachable now
source
nothing yet
Load cell / strain gauge
ADC (HX711)
MCU bus
reachable now
source
nothing yet
Door / reed / limit switch
GPIO, Zigbee
MCU bus
reachable now
source
nothing yet
Capacitive proximity / touch
I2C
MCU bus
reachable now
source
nothing yet
Flow / level / position encoders
4-20 mA, Modbus
Field bus
reachable now
source
nothing yet
Physics & health
Class
Env. sensitivity
Calibration
Failure signature
Cross-check
Common cause
EM-acoustic crossover
Pressure mat / FSR
creep
zero
creep
radar vitals
location
none identified
Load cell / strain gauge
temperature
span
creep, drift
FBG
structure
none identified
Door / reed / limit switch
alignment
none
chatter
camera, radar
door
none identified
Capacitive proximity / touch
humidity
baseline
baseline drift
camera
panel
none identified
Flow / level / position encoders
fouling
meter factor
stuck reading
redundant meter
process line
magnetostrictive level and position sensors
Physics & flux
Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).
Class
Physics group
Conjugate pair / energy flux
Characteristic scale
Resonance / aperture ("antenna") condition
Shared-space hook (rotation, scale, phase gate)
Pressure mat / FSR
SOLSolid-borne vibration, force, inertia
force F and displacement x (power F·v); piezoresistive FSR
kPa–MPa contact pressure; hysteresis and drift (FSR ~10 %, typ.)
quasi-static: no wave; contact compliance and electrode geometry set the aperture; scan-matrix settling time
R: F/v pair and the sensing axis. s: mass or stiffness and Z. Phase gate: stay below f0 (or model it), so the output follows real motion.
gauge factor ≈ 2; sensitivity ~2 mV/V at full scale (typ.); mechanical resonance f0 = (1/2π)√(k/m)
bridge excitation and low-noise amp; f0 sets bandwidth; temperature compensation
R: F/v pair and the sensing axis. s: mass or stiffness and Z. Phase gate: stay below f0 (or model it), so the output follows real motion.
Door / reed / limit switch
EMQQuasi-static / near-field EM
magnetic reed: H·B closes a switch; limit switch: contact force
operate field of order mT (reed switches are rated in ampere-turns, typ.); no signal bandwidth
sensor ≪ λ; contact debounce time ~ ms; magnet gap sets threshold
R: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.
Capacitive proximity / touch
EMQQuasi-static / near-field EM
quasi-static E-field: displacement current through a fringing capacitance (V·I)
R: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.
Flow / level / position encoders
MIXComposite or multi-physics
flow: Δp or ultrasonic transit time; level: acoustic/radar time of flight; encoder: optical or magnetic phase
ranges metres; time of flight c·t/2; encoder PPR
depends on principle; ultrasonic and radar level sensors need beam aperture ≳ λ and a clean near-field (blanking zone)
Split into its component modalities before mapping; each part uses its own group.