Bio & wearables has 4 classes on or near the body: ECG / biopotential, PPG / SpO2 / skin temperature, EMG / EEG, and the smart glasses / phone sensor bundle. They differ from room sensing because the sensor touches the subject: coupling to skin, not a radiating aperture, decides what is measured. The bundle is a device, not a physics, and is split into its component classes.
Flux and conjugate pair: Biopotentials: V·I, where ion currents in tissue are transduced to electron current at the electrode; PPG: photon flux through tissue, absorbed by haemoglobin (Beer–Lambert).
Characteristic scale: Skin–electrode impedance kΩ–MΩ; ECG band ~0.05–150 Hz; EMG ~20–500 Hz up to ~mV, EEG ~0.5–100 Hz at ~µV; PPG at 525–560, 660 and 940 nm with a pulsatile part ~1 % of DC (typ.).
Resonance / aperture condition: High input impedance (≥ 100 MΩ) and CMRR (> 100 dB, typ.) with a driven right leg make the electrode a quasi-static “antenna”; for PPG the LED–photodiode spacing sets penetration depth.
In the shared space: the hypothesis is that the device bundle is a natural place to test map fitting, since its parts see the same subject at the same moment; the shared clock, battery and mount are also common causes that can fake agreement. Not measured.
The same lumped network in four domains (impedance analogy).
Symposium rooms. Planned room: BIO. Context pack: BIO. Experts: bio-physics, bio-signal. Planned room BIO (2 agents), chaired by bio-physics; hot cells with SVD, MATH in S3.1; reviewed by the adversarial group in S2.4. Symposium plan (plan only, not launched).
Bio & wearables: requirements grid (4 classes)
4 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.
Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).
Class
Physics group
Conjugate pair / energy flux
Characteristic scale
Resonance / aperture ("antenna") condition
Shared-space hook (rotation, scale, phase gate)
ECG / biopotential
ELEElectrical power and biopotential
electrode potential V (ion flux transduced to electron flow V·I); µV–mV
high Z input, CMRR, shielding; electrode placement sets the sensed volume
R: V/I pair (voltage and current axes). s: impedance. Phase gate: anti-alias filter and CMRR keep real signal separate from pickup.
Smart glasses / phone sensor bundle
MIXComposite or multi-physics
bundle of camera, mic, IMU and other physics in one device
see the component classes
handled per component; the bundle shares a clock, battery and mount (common causes)
Split into its component modalities before mapping; each part uses its own group.
Scale
Class
Room x10
Building x300
Factory x5000
Compute at factory
Scale note
ECG / biopotential
20 kB/s
599 kB/s
10 MB/s
edge aggregator per floor
same as building
PPG / SpO2 / skin temp
10 kB/s
300 kB/s
5 MB/s
edge aggregator per floor
same as building
EMG / EEG
316 kB/s
9.5 MB/s
158 MB/s
zone edge aggregators; ship derived only
same as building
Smart glasses / phone sensor bundle
3.2 MB/s
95 MB/s
1.6 GB/s
reduce at node; fiber backbone + dedicated compute
same as building
Governance
Class
Maturity
Privacy
Provenance
ECG / biopotential
prototyped
high
project notes: module types note biopotential; cogs-sen0213; research C §4.5: wearable biosignal review PMC8587479 [E] (ECG 100-1000 Hz, 1 kHz covers most uses)
PPG / SpO2 / skin temp
possible
high
research C §4.5: wearable biosignal review PMC8587479 [E]; Pixel Watch PPG dataset, arXiv 2512.03988 [E] (about 68 Hz); rest typical
EMG / EEG
possible
high
project notes: silent speech radar note s3 (comparison); research C §4.5: PMC8587479 [E] (EEG 100-1000 Hz, EMG up to several kHz; sources disagree); rest typical