Research findings
Four research threads: modular mesh architecture, sensor health and voting, modality taxonomy and scale, and sensing ontologies. Each lists its findings and key citations.
The four threads
Four research threads run 21 Nov 2026 (America/New_York). Each report reads most sources through abstracts, records and summaries rather than full text, and labels its own opinions as such.
A. Modular mesh architecture
- Adopt the established fusion vocabulary instead of inventing one: the revised JDL levels (signal, object, situation, impact, process refinement) map cleanly onto cog topic families, with health as metadata across every level.
- The central hazard of fusing over a mesh is double counting: two estimates that share an upstream source make the result overconfident. Fused records should carry their lineage, and Covariance Intersection gives a safe answer when the correlation is unknown.
- Fault-tolerant fusion of redundant sensors (Marzullo 1990, Brooks–Iyengar 1996) only works if each source's value, uncertainty and status stay separate until fusion; ISO 13374, ROS diagnostics and the self-validating sensor all keep evidence and verdict as separate layers.
- Time sync quality varies by orders of magnitude and must be a declared capability: NTP gives milliseconds, PTP with hardware timestamps sub-microsecond, White Rabbit about 0.5 ns over 15 km of fiber.
- ROS 2, DDS and Holoscan converge on typed topics with QoS contracts and pluggable transports (zero-copy shared memory inside a node). WeftOS already has the shape but lacks a per-port contract (rate, bytes/s, latency budget, clock class); placement is NP-hard, so ADR-099 should start with heuristics.
- Steinberg, Bowman, White: Revisions to the JDL data fusion model (1999) — DTIC
- Julier, Uhlmann: estimation with unknown correlations (Covariance Intersection, 1997) — UNC
- Marzullo: Tolerating failures of continuous-valued sensors (1990) — NASA NTRS
- Lipiński et al.: White Rabbit sub-nanosecond sync (2011) — ISPCS
- Akidau et al.: The Dataflow Model (2015) — Google Research
- Macenski et al.: Robot Operating System 2 (2022) — arXiv
- Cardellini et al.: Optimal operator placement (DEBS 2016) — Tor Vergata
- ROS diagnostic_aggregator — docs.ros.org
B. Sensor health and voting
- Keep evidence separate and fuse it only at decision time: every fusion method with a guarantee (Chair–Varshney, Marzullo, Brooks–Iyengar) needs to know which source said what, and a merged stream loses that for good.
- Worst-wins across lanes is a 1-out-of-N vote. Its false-alarm rate grows with N: five lanes at 1% each give about 4.9% system false alarms, against about 0.1% for 2-of-5, for almost no gain in detection.
- Common-cause failure caps what redundancy can do (the IEC 61508 beta-factor): more voters cannot remove the shared part, so producers that share a host, firmware, model, power rail or link should count as one vote.
- Deployed sensors rarely fail cleanly: they spike, stick, drift and get noisy, and cloud systems fail 'gray', looking healthy to themselves while consumers suffer. Disagreement between producers is the most informative health signal.
- Graded suspicion with hysteresis beats binary flags (phi accrual, SWIM Suspect, Lifeguard's more-than-50x cut in false positives). At fleet scale, multi-stream change detection (Mei 2010) and false-discovery-rate control keep alarm counts from growing with fleet size.
- Chair, Varshney: Optimal data fusion in multiple sensor detection systems (1986) — IEEE TAES
- Brooks, Iyengar: Robust distributed computing and sensing algorithm (1996) — IEEE Computer
- Lamport, Shostak, Pease: The Byzantine Generals Problem (1982) — Microsoft Research
- Lundteigen, Rausand: CCF definition and classification (SIS book ch. 10) — NTNU
- Huang et al.: Gray Failure (HotOS 2017) — Microsoft Research
- Dadgar et al.: Lifeguard (2018) — arXiv
- Ni et al.: Sensor network data fault types (2009) — eScholarship
- Mei: Monitoring a large number of data streams (2010) — Biometrika
C. Modality taxonomy and scale
- Requirements span about nine orders of magnitude: a scalar sensor needs bytes per minute, a 128-channel lidar about 254 Mb/s, raw cameras gigabits per second, and a world-model latent moves at memory-bus speed. No single transport or schema serves all of them.
- Classify on independent axes, not physics alone: rate, bandwidth, latency, sync, compute per byte, data shape and reducibility. How far edge processing can shrink a stream decides how it scales.
- Link tiers form a ladder of about six rungs, from MCU bus to fieldbus, TSN Ethernet, 10-100 GbE with RDMA, PCIe/CXL, and shared memory. Move the consumer to the producer for large irreducible streams (radar cubes, raw I/Q, latents); move the stream up only after reduction.
- In a factory, cameras dominate the bytes but scalar points dominate the number of things to manage. Scale economies come from one identity scheme, one declaration format, one health model and one OTA path across thousands of nodes.
- Derived streams (latents, tracks, embeddings, health verdicts) are modalities too, and event-rate sensors (event cameras, CSI bursts, in-band telemetry) need per-topic rate caps, drop policies and a drop counter that is itself health evidence.
- Gallego et al.: Event-based Vision, a Survey (TPAMI 2022) — arXiv
- Ma, Zhou, Wang: WiFi Sensing with CSI, a Survey (2019) — ACM CSUR
- Du et al.: Overview of IEEE 802.11bf WLAN Sensing (2023) — arXiv
- Ouster OS1 lidar data rates — Ouster
- Analog Devices: MEMS accelerometers for condition monitoring — analog.com
- Sisinni et al.: Industrial Internet of Things (2018) — IEEE TII
- Zhang et al.: TSN for Industrial Automation (2024) — arXiv
- Das Sharma et al.: Introduction to CXL (2023) — arXiv
- Assran et al.: V-JEPA 2 (2025) — arXiv
D. Sensing ontologies
- No adopted ontology organises sensing by physics. Civilian standards sort by device or by observed property, military ones by discipline, signal intent, processing level or track, and nobody models the transduction chain (photoacoustic, EMAT, SAW/BAW, vibrometry). WeftOS has to add that thin layer itself.
- Anchor the observation core to W3C/OGC SOSA/SSN 2017 (track the 2023 draft), quantities to QUDT with SenML units kept on the wire, lineage to PROV-O, and health stages and states to ISO 13374 and NE107. None of them models per-producer health lanes.
- Borrow four structures from the military: the MASINT discipline axis as the top of a physics taxonomy, JDL levels as the stream class of derived data, track quality, age and provenance on every record (Link 16, Cursor-on-Target), and ELINT-style emitter descriptors. DoD named BFO and CCO its baseline in January 2024: publish a mapping, do not import them.
- The Palantir and Anduril lesson is architectural: typed, governed actions; entities as bags of components with mandatory provenance and an expiry; markings that propagate through derivation. Neither models transduction physics, per-producer health, link tiers, clock quality or latent streams.
- Recommendation: a small native WeftOS Sensing Ontology in Rust types, cog.toml and contract schemas, exported to Turtle or JSON-LD, with seven class groups. Rename levels now (fusion F0-F4, evidence E0-E5) before RuView's L0-L5 ladder and JDL's L0-L4 collide in a schema.
- W3C/OGC Semantic Sensor Network Ontology (2017 Recommendation) — W3C
- SSN 2023 edition (Working Draft) — W3C
- OGC SensorML 3.0 — OGC
- QUDT — qudt.org
- ODNI MASINT Primer (2022) — dni.gov
- Jensen et al.: The Common Core Ontologies (2024) — arXiv
- DoD adopts BFO and CCO as baseline (2024) — University at Buffalo
- Palantir: Ontology overview — palantir.com
- Anduril Lattice SDK: Entities overview — developer.anduril.com
- IEEE 1900.6 spectrum sensing interfaces — IEEE SA
- SigMF specification — GitHub