Omni Modal Sensor Symposium
Cog Explorer

Power & electrical

Power & electrical: 5 stream classes, with eight grid views.

Power & electrical: physics in brief

Power & electrical has 5 classes: current / energy metering (CT, smart meter), power quality / waveform capture at kHz, node / board telemetry (power draw, thermals), EMI / RF emission signatures and battery / BMS state. The family watches both the loads in a space and the sensing nodes themselves, so it is a modality (which equipment is running) and a health input for the rest of the grid.

  • Flux and conjugate pair: Electrical power P = V·I, with voltage and current as the conjugate pair; CTs use Faraday induction V = −dΦ/dt; EMI adds conducted V·I and radiated S = E × H.
  • Characteristic scale: Line frequency 50/60 Hz; the 50th harmonic needs sampling above ~6 kHz; shunts in mΩ; EMC bands 150 kHz–6 GHz (λ = 2 km–5 cm).
  • Resonance / aperture condition: Input matching, isolation and anti-alias filtering with bandwidth ≫ the harmonics; CT core and burden set the passband (a Rogowski coil needs an integrator); EMI near-field probes are ≪ λ and read E or H separately.

In the shared space: the hypothesis is that V·I fits the same conjugate-pair structure as p·v and E·H (the impedance analogy), giving power signals a defined place in the map, while board telemetry acts as a common-cause term rather than a sensed signal. Not measured.

Flux vectors in three kinds of physics: EM, acoustic and thermal diffusion Three panels. EM: E and H oscillate together and S = E x H always points along travel. Acoustic: pressure p and particle velocity v oscillate together and I = p v always points along travel. Thermal: a temperature step relaxes by diffusion; the profile spreads, the heat flux q = -k grad T shrinks, and nothing oscillates: diffusive, no propagating phase. Bottom row: the conjugate effort-flow pair whose product is the power flux in each case. Electromagnetic S = E × H (Poynting vector) E H (out of page) S E and H flip together, so S never reverses Acoustic I = p·v (sound intensity) p v (along travel) I p and v flip together, so I never reverses Thermal diffusion q = −k∇T (Fourier's law) hot x T(x) q (shrinks as ∇T relaxes) diffusive: no propagating phase profile spreads ~ √(αt); nothing oscillates Conjugate pairs (effort × flow = power flux): E (V/m) × H (A/m) → S (W/m²) wave: propagating phase, c ≈ 3×108 m/s p (Pa) × v (m/s) → I (W/m²) wave: propagating phase, c ≈ 343 m/s (air) T (K) × q/T (W/(m²·K)) → q (W/m²) diffusion: ∂T/∂t = α∇²T, no wave speed
Energy flux and its conjugate pair in EM, acoustic and thermal transport. Thermal transport is diffusive and has no propagating phase.

Front-end circuits for this family

Power & electrical: requirements grid (5 classes)

5 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.

Overview

ClassFamily / bandRateBandwidthLink tierMaturityProvenance
Current / energy metering (CT, smart meter)Power & electrical1 Hz-1/minbytes/sField buspossibletypical
Power quality / waveform (kHz)Power & electrical1-50 kS/s10-200 kB/sEthernet 1Gpossibletypical
Node / board telemetry (power draw, thermals)Power & electrical0.1-1 Hzbytes/sMCU busprototypedrepo
EMI / RF emission signaturePower & electrical (also EM: LF-HF)MS/s1-100 MB/s rawUSBpossibletypical
Battery / BMS statePower & electrical0.1-1 Hzbytes/sField buspossibletypical

Timing & bandwidth

ClassFamily / bandExamplesRateBandwidthTierLatencyJitterSync
Current / energy metering (CT, smart meter)Power & electricalnone yet1 Hz-1/minbytes/sT0 tricklesss
Power quality / waveform (kHz)Power & electricalnone yet1-50 kS/s10-200 kB/sT2 10 kB-1 MB/smsµsµs (synchrophasor)
Node / board telemetry (power draw, thermals)Power & electricalboard-telemetry cog (edge-node plan P0)0.1-1 Hzbytes/sT1 10 B-10 kB/ssss
EMI / RF emission signaturePower & electrical (also EM: LF-HF)none yetMS/s1-100 MB/s rawT3 MB/ssµsms
Battery / BMS statePower & electricalnone yet0.1-1 Hzbytes/sT0 tricklesss

Compute & storage

ClassComputeCan run onMemoryStoragePower
Current / energy metering (CT, smart meter)noneMCUbytesyearsself
Power quality / waveform (kHz)FFTMCU, SBCMBseventsself
Node / board telemetry (power draw, thermals)nonenodebyteslongnone
EMI / RF emission signatureFFT, MLSBC, GPUMBssignaturesW
Battery / BMS statenoneMCUbyteslongself

Link & mesh

ClassTransportLink tierReachUnitMesh status
Current / energy metering (CT, smart meter)Modbus, Wi-FiField busreachable nowsourcenothing yet
Power quality / waveform (kHz)EthernetEthernet 1Gneeds new linksource+processornothing yet
Node / board telemetry (power draw, thermals)in-nodeMCU busreachable nowsourceschema + vectors
EMI / RF emission signatureUSB SDRUSBreachable nowsource+processornothing yet
Battery / BMS stateSMBus, CANField busreachable nowsourcenothing yet

Physics & health

ClassEnv. sensitivityCalibrationFailure signatureCross-checkCommon causeEM-acoustic crossover
Current / energy metering (CT, smart meter)noneCT ratiophase swapboard telemetrypanelnone identified
Power quality / waveform (kHz)nonereferenceclippingvibrationfeedertransformer and motor hum; partner ac1
Node / board telemetry (power draw, thermals)nonenonesensor missingenergy meternodenone identified
EMI / RF emission signatureother emittersantennaoverloadcurrentantennapartial discharge emits RF and ultrasound; partner ac6
Battery / BMS statetemperaturecoulombSoC driftcurrentpacknone identified

Physics & flux

Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).

ClassPhysics groupConjugate pair / energy fluxCharacteristic scaleResonance / aperture ("antenna") conditionShared-space hook (rotation, scale, phase gate)
Current / energy metering (CT, smart meter)ELE Electrical power and biopotentialV·I; current transformer: Faraday induction V = −dΦ/dtburden resistor; 50/60 Hz primary; CT core saturationcore and burden set the passband; Rogowski coil gives dΦ/dt (integrator needed); clamp geometryR: V/I pair (voltage and current axes). s: impedance. Phase gate: anti-alias filter and CMRR keep real signal separate from pickup.
Power quality / waveform (kHz)ELE Electrical power and biopotentialP = V·I; harmonics up to kHzsampling ≥ 2× harmonic order × 50/60 Hz (> 5 kHz at 50 Hz, > 6 kHz at 60 Hz for the 50th harmonic); 16-bit ADC (typ.)anti-alias filter and isolation; sensor bandwidth ≫ harmonicsR: V/I pair (voltage and current axes). s: impedance. Phase gate: anti-alias filter and CMRR keep real signal separate from pickup.
Node / board telemetry (power draw, thermals)ELE Electrical power and biopotentialV·I on shunts; board temperature sensorsshunt mΩ; telemetry rate ≤ 1 Hz (typ.)shunt + amp bandwidth; thermal τ of the sensor on the boardR: V/I pair (voltage and current axes). s: impedance. Phase gate: anti-alias filter and CMRR keep real signal separate from pickup.
EMI / RF emission signatureEMW Propagating EM (RF to THz)conducted V·I and radiated S = E × H; near-field probes read E or H separatelyEMC bands 150 kHz–6 GHz (λ = 2 km–5 cm)near-field probe ≪ λ (loop/stub) or broadband antenna ~λ/2; spectrum-analyzer resolution bandwidthR: E/H pair fixes the polarisation and angle-of-arrival axes. s: Z0 and c fix amplitude and length units. Phase gate: aperture ≳ λ/2 plus a shared LO.
Battery / BMS stateELE Electrical power and biopotentialV·I at cell terminals; electrochemical state (chemical potential μ)cell impedance mΩ; OCV–SOC curve; coulomb countercurrent shunt/gauge accuracy; temperature compensation; sampling vs. load transientsR: V/I pair (voltage and current axes). s: impedance. Phase gate: anti-alias filter and CMRR keep real signal separate from pickup.

Scale

ClassRoom x10Building x300Factory x5000Compute at factoryScale note
Current / energy metering (CT, smart meter)32 B/s949 B/s16 kB/scentral is finesame as building
Power quality / waveform (kHz)501 kB/s15 MB/s251 MB/szone edge aggregators; ship derived onlysame as building
Node / board telemetry (power draw, thermals)100 B/s3 kB/s50 kB/scentral is finesame as building
EMI / RF emission signature100 MB/s3 GB/s50 GB/sreduce at node; fiber backbone + dedicated computesame as building
Battery / BMS state32 B/s949 B/s16 kB/scentral is finesame as building

Governance

ClassMaturityPrivacyProvenance
Current / energy metering (CT, smart meter)possiblemediumtypical
Power quality / waveform (kHz)possiblemediumtypical
Node / board telemetry (power draw, thermals)prototypedlowproject notes: ventuno q cog plan note P0; telemetry.v1
EMI / RF emission signaturepossiblelowtypical
Battery / BMS statepossiblelowtypical