Omni Modal Sensor Symposium
Cog Explorer

Industrial & machine: family overview

3 classes from machines: CAN bus signals, PLC tags and motor drive or spindle telemetry.

Overview

Industrial & machine has 3 classes: CAN / CAN-FD bus signals, PLC tags (Modbus, OPC-UA) and motor drive / spindle telemetry. Two of the three are already digital: the machine has done the sensing and publishes values, so what matters is the bus and the scan cycle. Motor-drive telemetry still carries real physics: phase currents, spindle torque and vibration.

3 classes · 1 circuit card · Requirements grid for this family

What it senses

  • Machine state published as values on a bus.
  • Phase currents, torque and vibration of drives.

Modalities in this family

3 classes, grouped by physics. Open the requirements grid for bandwidth, data rate, link tier and the other views.

Digital, timing and derived 2

Composite or multi-physics 1

Key physics

  • Flux and conjugate pair: Bus classes: differential V·I on a transmission line carrying bits, with no sensed flux; drives: electrical V·I, mechanical τ·ω at the spindle and vibration F·v.
  • Characteristic scale: CAN twisted pair Z0 ≈ 120 Ω, CAN-FD to ~5–8 Mb/s, ~40 m at 1 Mb/s; Ethernet 100 Ω differential, RS-485 120 Ω; drive PWM ~4–16 kHz (typ.).
  • Resonance / aperture condition: Terminate both bus ends at the line impedance so the signal propagates without reflections, and keep stubs short; drive current sensors need bandwidth above the PWM harmonics, and mechanical resonance limits what is observable.

In the shared space: the hypothesis is that bus values enter the ring as already-labelled time series (an embedding plus a scan-cycle timestamp), while drive telemetry can be mapped alongside the vibration and power classes. Not measured.

Strengths and limits

Strengths

  • The machine has already done the sensing, so the value is clean and cheap to read.
  • Scan cycles are regular, which helps alignment.

Limits

  • The bus and scan cycle, not the physics, limit what is available.
  • Protocol access and write safety need care.

Front-end circuits

Open questions for the symposium

  • How are bus time stamps related to the symposium time base?
  • Which machine signals are trustworthy enough to count as ground truth?

Symposium room. Planned room: IND. See the plan and the run of show. Room sessions are marked Coming; no results exist yet.

Source data

Datasets, standards, tools and datasheets recorded for this family. Browse all sources for this family.

Parts in the Cog Explorer

Parts in the Cog Explorer. 0 in the catalog, 2 proposed (pending review), of 2 named parts. See coverage for this family. Open a named part, or browse the WeftOS Cog Explorer.

  • MCP2518FD proposed (pending review)
  • TCAN1042 proposed (pending review)

Update log

  • v3 Family page created with overview, modalities, physics, strengths and limits, open questions and this log.