CO2 (NDIR)
CO2 (NDIR) — a Tested class in Environmental. Sources, example devices and what it measures.
What it measures
EnvironmentalTestedOptical / infrared photons
This class sits in the Environmental coverage zone of the schematic sensor room. The zone is a layout, not measured coverage.
In the grid. Environmental (also EM: IR).
Physics. Beer–Lambert absorption at 4.26 µm (CO2 band)
Characteristic scale. λ = 4.26 µm; path length ~ cm; thermopile detector τ ~ 10s of ms
Resonance or aperture. IR source + narrow bandpass filter on the CO2 line (resonance) and a reference channel (3.9 µm); optical cavity length L ≫ λ
- Rate1/60 Hz
- Bandwidthbytes/min
- Link tierMCU bus
- Can run onMCU
- Reachreachable now
Listed on the hardware pages: Acoustic, biopotential, gas and environmental hardware, Overlap: boards that serve several modalities. Those notes are example boards and planning overlap, not a lab test of this class.
Sources
HITRAN molecular spectroscopic database
Line strengths for TDLAS/NDIR/photoacoustic gas sensing (em12, em24, en2)
CO2 accuracy +/-(40 ppm+5%), ASC behaviour
All-in-one PM/RH/T/VOC/NOx/CO2
Devices
- SCD41Sensirionphotoacoustic CO2In the WeftOS Cog ExplorerDatasheet
- XENSIV PAS CO2Infineonphotoacoustic CO2proposed (pending review)Datasheet
- SEN66SensirionPM/RH/T/VOC/NOx/CO2 moduleproposed (pending review)Datasheet
Open questions for the symposium
These are the open questions for the Environmental family, which this class belongs to.
- Do these classes join the shared space at all, or act as context and health inputs?
- How should slow channels be time-aligned with fast ones?