Contact & physical has 5 classes that read contact, load and state directly: pressure mat / FSR, load cell / strain gauge, door / reed / limit switch, capacitive proximity / touch, and flow / level / position encoders. They are the simplest sensors in the grid and often the most trusted, because a switch or a load cell leaves little room for interpretation, which makes them useful ground truth for the richer classes.
Flux and conjugate pair: Mostly F·v (force and velocity; stress and strain rate), converted to V·I by a bridge or resistive element; capacitive and reed sensing use quasi-static E or H fields.
Characteristic scale: Contact pressure kPa–MPa; strain-gauge factor ≈ 2 with ~2 mV/V at full scale (typ.); capacitance ~pF with fF changes; reed thresholds ~a few mT (typ.).
Resonance / aperture condition: Quasi-static, so no wave: compliance, electrode or magnet geometry is the aperture; a mechanical resonance f0 = (1/2π)√(k/m) bounds load-cell bandwidth; switches need ~ms debounce.
In the shared space: the hypothesis is that these low-dimensional, near-binary signals act as anchor labels for fitting and checking maps rather than as embeddings to be rotated. Not measured.
This family is a coverage zone in the schematic sensor room. The zone is a layout, not measured coverage.
The same lumped network in four domains (impedance analogy).
Symposium rooms. Planned room: PHY. Context pack: PHY. Experts: phy-physics, phy-signal. Planned room PHY (2 agents), chaired by phy-physics; hot cells with MATH in S3.1; reviewed by the adversarial group in S2.4. Symposium plan (plan only, not launched).
Contact & physical: requirements grid (5 classes)
5 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.
Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).
magnetic reed: H·B closes a switch; limit switch: contact force
operate field of order mT (reed switches are rated in ampere-turns, typ.); no signal bandwidth
sensor ≪ λ; contact debounce time ~ ms; magnet gap sets threshold
R: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.
R: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.