Inertial, magnetic, position has 4 classes that say where a node or body is and how it moves: the IMU 6/9-DoF, magnetometer / magnetic anomaly sensing, GNSS position fused with an IMU, and proprioception (joint state). In the grid it is the pose layer: other modalities need its output to put their readings into a common physical frame.
Flux and conjugate pair: Inertial: F = ma on a proof mass and Coriolis F = −2m Ω × v on a driven mass (power F·v); magnetic: H·B energy, with B read by Hall or AMR elements; GNSS: received S = E × H; joints: torque × angular rate τ·ω.
Characteristic scale: Earth field ~25–65 µT; accelerometer resonance ~kHz–10 kHz and gyro drive ~10–30 kHz (typ.); GNSS L1 at 1575.42 MHz, λ ≈ 19 cm, ≈ −130 dBm at the antenna (typ.).
Resonance / aperture condition: Proof-mass resonance sets bandwidth and the gyro drive mode must stay locked; magnetometers are ≪ λ and need hard- and soft-iron calibration; the GNSS patch needs a ground plane and a known phase centre.
In the shared space: this family gives the physical frame the other sensors are registered in; the hypothesis is that a calibrated pose makes the embedding rotation between other modalities easier to fit, but that link is not measured.
This family is a coverage zone in the schematic sensor room. The zone is a layout, not measured coverage.
Energy flux and its conjugate pair in EM, acoustic and thermal transport. Thermal transport is diffusive and has no propagating phase.
Symposium rooms. Planned room: IM. Context pack: IM. Experts: im-physics, im-signal. Planned room IM (2 agents), chaired by im-physics; no hot cells; reviewed by the adversarial group in S2.4. Symposium plan (plan only, not launched).
Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).
sensor ≪ λ; soft-iron and hard-iron calibration (ellipsoid fit) makes the reading a real field direction
R: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.