Ultra-sensitive magnetometry (fluxgate, OPM, SQUID)
Ultra-sensitive magnetometry (fluxgate, OPM, SQUID) — a Possible class in Electromagnetic spectrum. Sources, example devices and what it measures.
What it measures
Electromagnetic spectrumPossibleQuasi-static / near-field EM
This class sits in the Electromagnetic spectrum coverage zone of the schematic sensor room. The zone is a layout, not measured coverage.
In the grid. EM: static/ELF, field sensing.
Physics. H·B energy; B and magnetisation M (flux quantum Φ0 ≈ 2.07×10-15 Wb for SQUID)
Characteristic scale. μ0; Earth field ~25–65 µT; Larmor f = γB (~3.5 Hz/nT ¹³³Cs, ~7 Hz/nT ⁸⁷Rb)
Resonance or aperture. fluxgate: core driven into saturation at ~kHz; OPM: vapour-cell Larmor resonance; SQUID: Josephson loop; all ≪ λ
- Rate100 Hz-10 kHz
- Bandwidth1-100 kB/s
- Link tierUSB
- ComputeDSP, noise cancellation
- Can run onSBC
- Reachneeds new infra
Listed on the hardware pages: Inertial, magnetic, force, position, GNSS and fiber hardware, Overlap: boards that serve several modalities. Those notes are example boards and planning overlap, not a lab test of this class.
Sources
Kitching (2018) Chip-scale atomic devices, Applied Physics Reviews 5:031302 (OPMs, CSACs)
Sensitivity and SWaP of chip-scale OPMs and atomic clocks
NOAA World Magnetic Model / EMAG2 magnetic anomaly grid
Main-field reference to subtract for im2 anomaly sensing
Devices
Open questions for the symposium
These are the open questions for the Electromagnetic spectrum family, which this class belongs to.
- Which coherent RF classes (Wi-Fi CSI arrays, mmWave radar, UWB) can share one map first?
- How should raw I/Q and radar cubes be bundled given the mesh ceiling?
- Can one rotation plus one scale align EM embeddings with acoustic ones?