Omni Modal Sensor Symposium

Physics by sensor family

Conjugate pair, impedance, wave speed and aperture conditions for every family.

Physics by sensor family

One row per physical family. Each row names the pair of quantities whose product is the energy flux, the impedance and wave speed that set the scale, and the size or resonance condition a transducer must meet to pass real propagating flux rather than stored (reactive) energy, offset or pickup. Values are standard engineering figures; ~ marks approximations. The per-class annotations live in the grid's Physics & flux view and agree with this table. Composite classes (em20 thermoacoustic, em24 photoacoustic, en8 weather, ph5 encoders, bi4 wearable bundle, in3 drive telemetry) are split into their component rows before any mapping.

FamilyConjugate pair / energy fluxImpedance ZWave speed cResonance / aperture ("antenna") conditionWhat "real propagating flux" means hereExample grid classes (ids)
RF far-field (Wi-Fi, BLE, LoRa, cellular, GNSS)E and H; Poynting S = (1/μ0)(E × B) = E × HZ0 = √(μ0/ε0) ≈ 377 Ω in free space; antenna feeds matched to ~50 Ωc ≈ 3×108 m/s; λ = c/f: ~35 cm at 868 MHz, ~19 cm at 1575 MHz (GNSS L1), 12.5 cm at 2.4 GHzλ/2 dipole (~6 cm at 2.4 GHz) or patch ~λ/2 in the substrate, impedance-matched; electrically small antennas pay in bandwidth and efficiency (Chu limit, Q ≳ 1/(ka)3)Power delivered to a matched load from a radiated field beyond the near-field zone (r ≫ λ/2π; far field r > 2D2/λ for aperture D); RSSI is that power, not confidencerf4, rf12, rf13 (UHF), rf14, im3, ti1, ne3, rf7, rf8, rf9, rf10, rf15, pw4, em4 (HF), em7 (radiometry)
Wi-Fi CSI (single antenna and coherent array)E and H; S per subcarrier, sampled as the complex channel response H(f)Z0 ≈ 377 Ω; 50 Ω RF chainc ≈ 3×108 m/s; λ 12.5 cm (2.4 GHz), ~5–6 cm (5–6 GHz)Single node: one PCB or chip antenna (~λ/4–λ/2). Array: element spacing ≤ λ/2 and a shared local oscillator (LO) so that inter-element phase gives angle of arrivalMultipath amplitude and phase across subcarriers. Single-antenna phase is not coherent packet to packet (CFO, SFO, timing offset) until those are removed; only a coherent array's phase differences are physicalrf1, rf2, rf3, rf11
mmWave FMCW radar (24 / 60 / 77 GHz)E and H; echo power from the radar equation (∝ 1/R4)Z0 ≈ 377 Ωc; λ ≈ 12.5 mm (24 GHz), 5 mm (60 GHz), ~3.9 mm (77 GHz)Patch arrays at λ/2 pitch (~2.5 mm at 60 GHz), often antenna-in-package; TX and RX share one chirp LO; range resolution c/(2B) (~3.75 cm for B = 4 GHz)Beat frequency (range) and chirp-to-chirp phase (Doppler, micro-motion) of echoes mixed against the same LO; leakage, clutter and multipath ghosts are not targetsra1, ra2, ra3, ra4, ra5, ra6, ra9, em8
UWB radar and rangingE and H; pulse or wideband energyZ0 ≈ 377 Ωc; 3.1–10.6 GHz, λ ~3–10 cmWideband antenna (planar monopole, bowtie, Vivaldi) matched across ≥ 500 MHz with low pulse dispersion; range resolution ~c/(2B). Microwave CW Doppler and through-wall radar use the same λ/2 aperture rulesThe first-path (leading-edge) arrival, not the strongest path; timestamps on a shared or calibrated clock. Phase-based Bluetooth ranging uses tone phase across channelsrf6, ra7, rf5, ra8, ra10
Sub-THz / THzE and H; SZ0 ≈ 377 Ωc; 0.1–10 THz, λ 3 mm–30 µmOn-chip antennas, horns and lenses with aperture D ≫ λ for a narrow beam; TDS uses photoconductive antennas gated by a femtosecond laser; strong water-vapour absorption linesCoherent detection (heterodyne LO or optical gating) of the transmitted or reflected field; thermal background and standing waves are artefactsem9, em10
Quasi-static E/H, inductive, eddy-current, NFCReactive energy ½εE2 and B2/2μ0 (H·B); E and H not locked together, so no net Poynting flux until radiation startsWave impedance in the near field is above 377 Ω next to a small electric dipole and below 377 Ω next to a small loop, tending to 377 Ω beyond ~λ/2π; skin depth δ = √(2/(ωμσ)) (~66 µm in Cu at 1 MHz)No propagation over the sensing range; λ ≈ 22 m at 13.56 MHz, 6000 km at 50 HzStructure ≪ λ, read by coupling: mutual inductance, an LC resonance f = 1/(2π√(LC)) with Q, a capacitance bridge, or a high-impedance electrode; target within ~one coil radiusOnly the in-phase (resistive) part of the coupling transfers energy: eddy loss, load modulation, displacement current into a body. Reactive energy sloshing back and forth is private to the sensorem1, em3, em5, em21, em22, ph3, ph4, en7, rf13 (NFC)
Magnetometry (fluxgate, OPM, SQUID, AMR/Hall)H and B; energy density B2/2μ0, B = μ0(H + M)Not a wave impedance; scale set by μ0 and the sensor's transfer (V/T)Quasi-static (DC to ~kHz); Earth field ~25–65 µTAll ≪ λ. Fluxgate: core driven to saturation at kHz. OPM: vapour-cell Larmor resonance f = γB (~3.5 Hz/nT Cs, ~7 Hz/nT 87Rb). SQUID: Josephson loop counting flux quanta Φ0 ≈ 2.07×10−15 Wb. Hall: VH = IB/(nqt); AMR: bridgeField from the source, separated from sensor offset, hysteresis, heading error and nearby soft or hard ironem2, im2
Optical visible / NIR (cameras, lidar, ToF)E and H at ~1014 Hz; detectors are square-law (intensity), photon energy hc/λZ = Z0/n (~260 Ω at n ≈ 1.45)c/n; λ ~0.4–1 µm, lidar 905 / 1550 nmLens or stop aperture D ≫ λ, diffraction limit ~1.22 λ/D; photon energy above the band gap (Si cut-off ~1.1 µm); ToF and FMCW lidar add a modulation or optical LO referencePhoton count per pixel and, for ToF/lidar, round-trip delay or modulation phase; interferometry (LDV, FMCW lidar) keeps optical phase, ordinary cameras discard itop1, op2, op3, op4, op5, op6, op9, op10, op12, op13, op15, em13, em19, em12, en2, bi2
Thermal IR (microbolometer, thermopile, PIR)E and H at ~30 THz; radiant exchange ∝ ε σSB(Tscene4 − Tdet4)Z0/n; Ge and chalcogenide opticsc; LWIR 8–14 µm (300 K peak ~9.7 µm by Wien)Absorber over a λ/4 cavity (~2.5 µm for 10 µm), pixel pitch ~12–17 µm, thermal time constant τ = C/G (~10 ms microbolometer); PIR is pyroelectric (responds to dT/dt) behind a Fresnel lensNet radiative exchange between the scene and the detector's own temperature; the detector housing, optics and self-heating add their own flux and driftop7, op8, op11, em11
UV, X-ray, gammaPhoton energy flux; UV still behaves as a field, X-ray and gamma interact by photon counting and energy depositionUV: Z0/n; X/gamma: no useful impedance, attenuation length 1/μ insteadc; UV 10–400 nm, X-ray ~0.01–10 nm (keV), gamma above ~100 keVUV: band-gap or solar-blind detector with optics. X/gamma: no antenna; stopping thickness (scintillator, CZT, HPGe) and collimation set efficiency and directionCounts and deposited energy (pulse height) from the source above the background spectrum; pile-up and dead time are detector effectsem14, em15, op14, em16, em17, en6
Airborne acoustic (mics, arrays)Pressure p and particle velocity v; intensity I = p·vSpecific acoustic impedance ρc ≈ 413 rayl (air, 20 °C)c ≈ 343 m/s; λ 34 cm at 1 kHz, ~17 mm at 20 kHz, ~17 m at 20 HzDiaphragm and Helmholtz port resonances placed at or above the top of the band; arrays at d ≤ λ/2 (~8.6 cm at 2 kHz) to avoid spatial aliasingIn the far field p and v are in phase (p = ρc·v) and carry net intensity; close to a source they are partly in quadrature (reactive). A pressure mic sees p only; intensity needs a p–p or p–v probeac1, ac2, ac3, ac9, ac10
Ultrasonic in air (ranging, sonar, PMUT/CMUT)p and v; I = p·vAir ≈ 413 rayl against PZT ~30 MRayl: a ~7×104 mismatchc ≈ 343 m/s; λ ≈ 8.6 mm at 40 kHz; absorption grows fast with frequency (~1 dB/m order at 40 kHz)Bulk piezo: thickness resonance plus a quarter-wave matching layer, Zm = √(Z1Z2) (~0.1 MRayl for PZT to air) and λ/4 thick in the layer. PMUT/CMUT: thin membranes whose resonance is set by diameter and thickness, naturally closer to air's impedance; array pitch ~λ/2Echo arrival time and Doppler from a resonant, matched element; ringing after transmit and cross-talk are not echoesac4, ac5
Underwater acousticp and v; I = p·vρc ≈ 1.48 MRayl (water)c ≈ 1500 m/s (varies with temperature, salinity, depth); λ 15 cm at 10 kHzPZT (~30 MRayl) with a ~7 MRayl matching layer (√(30 × 1.48)); arrays at λ/2 at the design frequency; hydrophones smaller than λ are omnidirectionalPressure waves that reached the element through the water path (with the local sound-speed profile), not flow noise or hull vibrationuw1, uw2, uw3, uw4
Solid-borne vibration, acoustic emission, seismicForce F and velocity v (stress σ and particle velocity); P = F·vρc of the solid (~46 MRayl steel, longitudinal); ρcA for a rod~5.9 km/s longitudinal, ~3.2 km/s shear in steel; ~1–6 km/s in rock; slower surface and Lamb modesCouplant or stiff mount; accelerometers flat below their mounted resonance f0 = (1/2π)√(k/m); geophones (moving coil) flat in velocity above their natural frequency; AE sensors resonant or wideband in the 100 kHz–1 MHz band; EMAT coil pitch = λacoustic/2Elastic waves arriving through the structure; mount resonance, cable motion and electrical pickup are artefactsac6, ac7, ac8, em22, in3
Inertial MEMS (accelerometer, gyro)F and v on a proof mass; P = F·vMechanical oscillator impedance √(km)No wave inside the device; it rides on the motion of its mountProof-mass resonance f0 sets the usable band (accelerometer flat to a fraction of f0); gyros drive a resonator and sense Coriolis force F = −2m Ω × v, bandwidth set by the drive–sense mode splitInertial motion of the body the IMU is fixed to; vibration rectification, mount resonance, bias drift and temperature are private errorsim1, im4, ac7, bi4
Force, strain, pressure matsF and v (stress and strain rate); mostly quasi-static, so flow is tinyLoad-path stiffness; Z of the structureBelow structural resonance; quasi-staticGauge on the load path: strain gauge ΔR/R = GF·ε (GF ≈ 2 for metal foil), FSR or capacitive cells; stay below mount and mat resonanceLoad that actually passes through the sensing element, not shunted around it; creep, hysteresis and temperature are privateph1, ph2, ph5, im4
Thermal conduction (temperature, DTS)T and entropy flux q/T; Fourier heat flux q = −k∇TNo characteristic impedance; effusivity e = √(kρcp) sets the surface response, diffusivity α = k/(ρcp) (cp = specific heat)No true wave: diffusive, with diffusion length √(α/(πf)) replacing λThermal time constant τ = C/G of the probe; good thermal contact and radiation shielding; DTS reads the Raman anti-Stokes/Stokes ratio along a fibreHeat conducted from the medium being measured; self-heating, radiation and the probe's own lag are privateen1, fb2 (DTS), pw3
Chemical and particulate transportConcentration c and chemical potential μ; Fick flux J = −D∇cNone; calibration gain (sensor-specific)No wave; diffusion time τ ~ L2/D (D ~10−5 m²/s for gases in air) plus airflowInlet, membrane, diffusion barrier or heater cycle sets the response; NDIR cells set path length (Beer–Lambert); particle counters size by light scatteringSpecies that reached the sensing surface or optical path from the air being sampled; cross-sensitivity, poisoning and drift are privateen2, en3, en4, en5
Electrical power and biopotentialVoltage V and current I; P = V·ISource and input impedance (skin–electrode ~kΩ–MΩ; mains source mΩ–Ω)Lumped at these frequencies; line frequency 50/60 HzInput impedance far above source impedance, high common-mode rejection, anti-alias filtering, sample rate ≥ 2× bandwidth; CTs and shunts sized to the current rangeThe source's own V and I (heart, muscle, load), separated from mains pickup, motion artefact and electrode driftbi1, bi3, pw1, pw2, pw3, pw5
Fibre (DAS, FBG)Optical E and H guided in the core; S along the fibreZ0/n, neff ~1.45–1.47 (silica)c/n ≈ 2×108 m/s; λ ~1550 nmFBG Bragg condition λB = 2·neff·Λ (Λ ~535 nm at 1550 nm), shift ~1.2 pm/µε and ~10 pm/K; DAS gauge length and pulse width set spatial resolution (~c·τp/(2n))Phase or wavelength change of guided light caused by strain or temperature at a known position on the fibre; laser phase noise and polarisation fading are privatefb1, fb2
Timing, network and derived (digital)No sensing flux: bits, time stamps, embeddings; the wire still carries V·ILine impedance (CAN 120 Ω, Ethernet 100 Ω differential)Signal speed in the cable ~0.6–0.8 cTermination and clock quality: a quartz or atomic resonator (quartz Q ~104–106) defines the time baseNothing physical: these enter the fusion only as time labels or embeddings; their health is the clock, the link and the provenanceti1, ti2, ti3, ne1, ne2, ne4, in1, in2, de1, de2, de3, de4, de5, de6, de7, de8, de9, de10

Impedance analogies across domains

The same bookkeeping works in every domain that has a pair of power-conjugate variables: an effort that pushes and a flow that moves, whose product is power. Storage comes in two forms (inertia-like and compliance-like), loss in one, and a wave medium has a characteristic impedance built from the two stores. This page uses the impedance analogy: pressure ↔ voltage, volume velocity ↔ current, acoustic mass (inertance) ↔ inductance, acoustic compliance ↔ capacitance, and for mechanics force ↔ voltage, velocity ↔ current. The mobility analogy swaps these: force ↔ current and velocity ↔ voltage, so mass maps to capacitance and compliance to inductance. Both are correct; mixing them in one circuit is the usual source of error.

DomainEffort variableFlow variableInertia-likeCompliance-likeDissipationCharacteristic impedance
Electrical (lumped)Voltage VCurrent IInductance L (V = L·dI/dt)Capacitance CResistance R√(L/C); for a transmission line √(L′/C′) per unit length (e.g. 50 Ω coax)
EM waveE (V/m)H (A/m)Permeability μ (stores magnetic energy)Permittivity ε (stores electric energy)Conductivity σ√(μ/ε); Z0 ≈ 377 Ω in vacuum; lossy medium √(jωμ/(σ + jωε))
Acoustic (lumped, in a duct or port)Pressure pVolume velocity U (m³/s)Inertance MA = ρl/ACompliance CA = V/(ρc2)Acoustic resistance RA (viscous and radiation loss)ρc/A for a plane wave in a duct of area A; specific impedance ρc ≈ 413 rayl (air), ≈ 1.48 MRayl (water)
Mechanical (impedance analogy)Force FVelocity vMass mCompliance 1/kDamper b√(km) for a mass–spring; ρcA for a rod or bar wave
ThermalTemperature TEntropy flux Ṡ = q/T (power-conjugate), or heat flow q in the common pseudo-analogy (T·q is not a power)None: heat has no inertiaHeat capacity Cth = ρcpVThermal resistance Rth = L/(kA)None: diffusive, not a wave. Time constant τ = RthCth; a semi-infinite surface has a frequency-dependent impedance (per area) T/q = 1/(e√(jω)) with effusivity e

The missing thermal inertance is the reason heat sensors behave as low-pass filters with a predictable phase lag and never resonate. Every other row has both stores, so it can ring; its wave form reflects at an impedance step and can be matched with a quarter-wave section.

Transducers as wavelength-matched antennas

Every transducer converts between a guided signal (a voltage on a wire, a charge on a capacitor) and a flux in a medium. It does that efficiently only when its size or its resonance is matched to the wavelength, or for a non-wave domain to the relevant time constant. Away from that condition the device mostly stores energy reactively, and what it reports is dominated by its own coupling, offsets and pickup rather than by the field it was meant to sense.

EM and acoustic plane waves: fields in phase, energy flux along the direction of travel Top: an electromagnetic plane wave travelling right; E (vertical) and H (drawn in an oblique out-of-page plane) rise and fall together, their ratio is the free-space impedance Z0 = E/H of about 377 ohm and the Poynting vector S = E x H points along the direction of travel at c of about 3e8 m/s. Bottom: an acoustic plane wave in air; pressure p and particle velocity v are in phase, p/v = rho c of about 413 rayl, the intensity I = p v points along travel at c of about 343 m/s, and a row of air parcels bunches (compression) where p is high and spreads (rarefaction) where p is low. Animated: the phase travels right; illustrative, not to scale. Electromagnetic plane wave (free space) E and H transverse and in phase; energy flows along S S = E × H Z0 = E/H ≈ 377 Ω c ≈ 3×108 m/s S = E × H (W/m²) E field (V/m), vertical H field (A/m), drawn in an oblique out-of-page plane illustrative; not to scale Acoustic plane wave (air, 20 °C) p and v in phase, longitudinal; energy flows along I I = p·v ρc ≈ 413 rayl (Pa·s/m) c ≈ 343 m/s I = p·v (W/m²); p/v = ρc pressure p (Pa) particle velocity v (m/s) air parcels: bunch at high p illustrative; not to scale
Plane waves in two media: the EM wave carries S = E × H with Z0 ≈ 377 Ω; the acoustic wave carries I = p·v with ρc ≈ 413 rayl in air. Animated; values approximate.
  • EM dipole. A half-wave dipole (λ/2, ~6 cm at 2.4 GHz, cut slightly short in practice) resonates with ~73 Ω radiation resistance and radiates with high efficiency. Shrink it well below λ/2 and the Chu limit (Q ≳ 1/(ka)3) forces narrow bandwidth or loss. Arrays add aperture: spacing ≤ λ/2 avoids grating lobes at any steering angle.
  • Ultrasonic piezo. A piezo disc resonates in thickness when it is λ/2 thick in the ceramic. Because PZT (~30 MRayl) and air (~413 rayl) differ by ~7×104, a λ/4 matching layer of impedance Zm = √(Z1Z2) is the acoustic equivalent of a quarter-wave transformer on a line.
  • MEMS microphone. The port and back cavity form a Helmholtz resonator, fH = (c/2π)√(A/(V·Leff)), and the diaphragm has its own resonance; both are placed at or above the top of the audio band so the response below them is flat.
  • PMUT and CMUT. Piezoelectric and capacitive micromachined ultrasonic transducers are micro-realisations of ultrasonic antennas and arrays. A clamped membrane resonates at a frequency that scales as thickness over radius squared (f ∝ t/a2), so diameter picks the band; the light membrane couples to air far better than bulk ceramic; and arrays at ~λ/2 pitch (~4.3 mm at 40 kHz in air) steer beams just as patch arrays do in RF.
  • Bolometer. A microbolometer is a thermal "antenna": an absorber over a λ/4 cavity (~2.5 µm for 10 µm LWIR) captures the radiation, and its time constant τ = C/G plays the role that resonance plays elsewhere, setting bandwidth ~1/(2πτ) and trading against responsivity (∝ 1/G).
  • Fibre Bragg grating. An FBG is an optical resonator written into the core: it reflects a narrow band at λB = 2·neff·Λ, and strain or temperature move that band. The grating period is the "antenna" size, matched to half the guided wavelength.
Flux vectors in three kinds of physics: EM, acoustic and thermal diffusion Three panels. EM: E and H oscillate together and S = E x H always points along travel. Acoustic: pressure p and particle velocity v oscillate together and I = p v always points along travel. Thermal: a temperature step relaxes by diffusion; the profile spreads, the heat flux q = -k grad T shrinks, and nothing oscillates: diffusive, no propagating phase. Bottom row: the conjugate effort-flow pair whose product is the power flux in each case. Electromagnetic S = E × H (Poynting vector) E H (out of page) S E and H flip together, so S never reverses Acoustic I = p·v (sound intensity) p v (along travel) I p and v flip together, so I never reverses Thermal diffusion q = −k∇T (Fourier's law) hot x T(x) q (shrinks as ∇T relaxes) diffusive: no propagating phase profile spreads ~ √(αt); nothing oscillates Conjugate pairs (effort × flow = power flux): E (V/m) × H (A/m) → S (W/m²) wave: propagating phase, c ≈ 3×108 m/s p (Pa) × v (m/s) → I (W/m²) wave: propagating phase, c ≈ 343 m/s (air) T (K) × q/T (W/(m²·K)) → q (W/m²) diffusion: ∂T/∂t = α∇²T, no wave speed
Energy flux and its conjugate pair in EM, acoustic and thermal transport. Thermal transport is diffusive and has no propagating phase.

The common rule: pick the wavelength (or time constant) first, then size the aperture or resonance to it, then match its impedance to the medium. A sensor that meets all three passes real propagating flux; one that misses any of them still produces numbers, but they are mostly the sensor talking about itself.

Phase gates: resonance and matching conditions of four sensing front ends Four panels. A half-wave dipole: a standing wave with current maximum at the feed and voltage maximum at the ends when the length is about half a wavelength. A piezo ultrasound transducer with a quarter-wave matching layer whose impedance is the geometric mean of piezo (about 30 MRayl) and air (about 413 rayl), about 0.1 MRayl. A MEMS microphone: the sound port's air mass and the front-volume compliance form a Helmholtz resonator, drawn beside its mass-spring analogue. A MEMS accelerometer: a proof mass on springs, with a computed second-order frequency response (damping ratio 0.1) that is flat up to about f0/3, the usable band, then peaks at f0. Each panel states its phase gate. A · Half-wave dipole (RF) 2.4 GHz: λ ≈ 12.5 cm, so L ≈ λ/2 ≈ 6 cm I: peak at feed V: peak at ends standing wave, I and V 90° apart L ≈ λ/2 phase gate: L ≈ λ/2 → standing wave, input reactance ≈ 0 (R ≈ 73 Ω) B · Ultrasound piezo + λ/4 matching layer impedance step PZT → air is ~5 orders of magnitude PZT: Z1 ≈ 30 MRayl matching layer: Zm = √(Z1·Z2) ≈ 0.1 MRayl thickness t = λm/4 at f0 air: Z2 ≈ 413 rayl phase gate: t = λ/4 in the layer → reflections cancel at f0 ~0.1 MRayl is hard to make; air transducers use porous or multi-layer matching C · MEMS microphone: port, cavities, membrane Helmholtz: port air mass + front-volume compliance back volume (air spring) membrane front volume sound port (air mass) mass–spring analogue m m ↔ Ma = ρl/A (port) 1/k ↔ Ca = V/(ρc²) (front volume) phase gate: fH = (c/2π)·√(A/(V·l)) placed above the audio band D · MEMS accelerometer: proof mass f0 = (1/2π)·√(k/m) m k k frame moves with input a usable band f0/3 f0 log f schematic, ζ ≈ 0.1 |x/a| (dB) phase gate: use below ~f0/3 → gain flat, phase ≈ 0 computed: at f0/3 gain ≈ +1 dB, phase lag ≈ 4° (ζ = 0.1)
Resonance and aperture conditions that force correct phase: λ/2 dipole, quarter-wave matching layer, Helmholtz port, proof-mass resonance.
PMUT and CMUT micromachined ultrasound cells, and a steered 1-D array Left: a PMUT cell in cross-section, a membrane stack (passive layer, electrodes, piezo layer) over a cavity, flexing. Middle: a CMUT cell, a membrane with a top electrode over a vacuum gap above a doped-silicon bottom electrode, driven by a DC bias plus an AC signal. In both the membrane resonance is set by its diameter. Right: a 1-D array with pitch about half a wavelength; elements fire with a delay step, the wavelets add into a plane wavefront steered by about 25 degrees. Not to scale. PMUT cell piezoelectric micromachined transducer cavity top / bottom electrodes piezo layer (AlN or PZT) passive layer Si substrate membrane resonance set by diameter f0 ∝ t/a² (clamped plate: thickness t, radius a) CMUT cell capacitive micromachined transducer vacuum gap top electrode insulating post doped Si = bottom electrode membrane (SiN) membrane resonance set by diameter drive: VDC bias + vac; gap not to scale 1-D array, steered beam elements fire with a delay step Δτ beam θ ≈ 25° array pitch ~ λ/2 (no grating lobes) sin θ = c·Δτ / pitch
PMUT and CMUT cells as micro-scale ultrasonic antennas; arrays at ~λ/2 pitch steer the wavefront.