Omni Modal Sensor SymposiumOmni Modal
Cog Explorer

Shared geometric space

Plato’s Key and how the physics of each sensor family forms a rotation and scale map.

Plato's Key: a shared geometric space

Hazy Research (Cheng, Liu, Yau, Ré) published Plato's Key as a blog post on 2026-11-25. It studies factual recall in large language models. In our summary: the internal representation ("key") one model uses for a fact is mapped into another model's space and swapped in, and the test is whether the second model still recalls the fact. The reported finding is that one orthogonal rotation plus one global scale, fit in closed form, carries much of that structure between models. Everything below is as reported, for LLM factual-recall key swaps only.

The map, with Z̃ the mean-centred key matrices of the paired facts and μ the means:

  • zB = μB + s·R(zA − μA)
  • R = UVT, from the SVD Z̃BZ̃AT = UΣVT (orthogonal Procrustes)
  • s = ‖Z̃B‖F / ‖Z̃A‖F (one global scale)

Columns of Z̃ are paired facts, so both sides must have the same dimension. R = UVT is the orthogonal matrix that minimises ‖Z̃B − RZ̃A‖F; it may include a reflection (det −1). The scale shown is a norm ratio; the least-squares scale for that R would be tr Σ / ‖Z̃A‖F2, which is never larger.

Shared space: one rotation and one scale map modality A's frame onto modality B's Left: two coordinate frames with illustrative point clouds (not data) in three coloured groups; a ghost copy of cloud A is rotated by an orthogonal matrix R and scaled by s onto cloud B. The clouds include a mild leftover warp, so one rotation plus one scale cannot land perfectly; a nonlinear adapter can absorb that leftover. With scripts off the ghost loops; with scripts on, rotation and scale can be set by dragging or with sliders, and a toggle compares the strict one-rotation-plus-one-scale test (Procrustes, Umeyama) with a vec2vec-style nonlinear adapter. Schematic, not measured sensor data. Right: the closed-form map, and a schematic curve of accuracy kept versus principal components as reported for LLM factual-recall keys in Plato's Key. Two modality frames, one rotation + one scale illustrative point clouds, not data; colours mark corresponding groups modality A (e.g. Wi-Fi CSI) modality B (e.g. mmWave radar) μA μB s·R ghost: cloud A mapped by z ↦ μB + s·R(z − μA); leftover warp is schematic Map between frames zB ≈ μB + s·R (zA − μA) R: orthogonal (RᵀR = I), Procrustes fit via SVD s: one global scale; μ: frame means fit in closed form on paired samples As reported for LLM factual-recall keys (Plato's Key, Hazy Research): one rotation + one scale keeps a median 73% of self-swap accuracy. For sensors: a hypothesis to test. 256 principal components share of full-rotation accuracy kept (schematic curve) 16 256 512 components (log scale); no y values plotted as reported for LLMs (Hazy Research): 16 → 4% · 256 → 74% · 512 → 87%
One rotation plus one scale maps modality A into modality B’s coordinates. A toggle compares that strict test (Procrustes, Umeyama) with a vec2vec-style nonlinear adapter. Schematic clouds, not measured sensor data.
ResultReported valueMeaning for fusion
Form of the mapOne orthogonal Procrustes rotation plus one global scale, closed formAn edge between two modalities could be a small, auditable linear object rather than a trained network
Fit dataFewer than 5,000 factsSuggests edges might be fit from a modest set of paired events; how many sensor events are needed is unknown
Transfer vs self-swap accuracyMedian 41% transferred vs 55% self-swapThe within-model baseline is the right yardstick; absolute accuracy is not
RetentionMedian 73% of self-swap accuracy (range 60–93%)For LLMs a useful shared part exists but transfer is incomplete; the sensor analogue is to keep a private residual per modality
Cross-family vs within-family75% cross-family vs 69% within-familySimilar-looking sources need not map better; test, do not assume
Chains A→B→CMedian 99% of direct A→C; 47 chains, 40 at ≥ 95%, none below 92%For LLMs, composing maps lost little; a ring topology needs the same to hold for sensors
Dimension of the shared space256 principal components retain a median 74% of the full rotation's accuracy; 16 components 4%, 512 components 87%A low-dimensional shared subspace may carry most transferable structure; pick d from a retention curve
Scale of the study12 base LLMs, 20 model pairs, 8,800 factsEvidence is from language models only
Hypothesis for sensors. None of these numbers were measured on sensor data. The post itself lists other modalities as future work. On this site every use of rotation-plus-scale maps between sensors is a hypothesis to test, and the reported values are analogues, never targets.

How the physics forms the rotation + scale map

Our interpretation, not a finding: if two sensors observe the same event through different physics, the parts of their representations that describe the event (where, when, how fast, how strong) should be related by a change of basis and a change of units, which is what a rotation and a scale express. The physics tables suggest which physical facts constrain each part of the map. The rotation and scale in embedding space are not physical rotations; the claim is only that physics restricts what the shared linear structure can be.

  • The conjugate pair fixes the basis. Which two fields carry the flux (E/H, p/v, F/v, T/entropy flux) decides which axes a transducer can resolve: polarisation and angle of arrival for RF, pressure gradient and direction for acoustics, sensing axis for an IMU. That sets the orientation the rotation has to align.
  • Impedance and wave speed fix the global scale. Z converts effort to flow, c converts time to length (λ = c/f, range = c·t/2). If two encoders keep physical units, the same displacement or range differs between them by a factor these constants set, which one global scale s can absorb. After per-modality normalisation that factor is gone, and s mostly absorbs leftover gain differences.
  • The resonance / aperture condition fixes phase. Only a transducer matched to its wavelength (or time constant) passes real propagating flux with a stable, known phase. Reactive near-field energy, ringing, pickup and offsets have no counterpart in the other modality, so they should stay out of the shared space and live in the private residual.
Physical factFixesExampleFailure if wrong
Conjugate pair (which fields carry the flux)Basis and orientation of the shared axes (rotation R)A coherent Wi-Fi array resolves angle from E-field phase; a mic array resolves the same bearing from pressure delaysAxes the other sensor cannot see (polarisation, pressure-only mic vs velocity) are forced into the map and rotate noise into the shared space
Impedance Z and wave speed cGlobal scale s, and the time-to-length conversionRadar range from c ≈ 3×108 m/s vs ultrasonic range from c ≈ 343 m/s (temperature-dependent)A wrong or drifting c (air temperature, water sound-speed profile) shows up as a scale error that looks like a mapping fault
Resonance / aperture conditionWhich part of the signal has stable phase and enters the shared spaceFMCW radar phase against a shared LO; single-antenna CSI phase only after offset removalIncoherent phase, transducer ringing or reactive pickup enters the map and makes the fit unstable between sessions
Diffusive physics (thermal, chemical)A known low-pass and lag, not a waveBolometer τ = C/G; gas sensor τ ~ L2/DTreating a lagged, diffusive signal as instantaneous misaligns events and inflates the residual
Common time basePairing of events across modalities, the input to the fitPTP or GNSS PPS across nodesMis-paired events make any map look poor, or worse, make a shared clock error look like agreement

Still to be learned from data: the encoder for each modality and its version, the shared dimension d, the residual structure each modality keeps private, calibration against mount and room, and whether a linear map is enough at all for a given pair. Physics constrains the map; it does not supply it.

Parallels

Transducers as wavelength-matched antennas. An antenna is a transducer between a guided wave and a radiated one, and only works when its size or resonance matches λ. A rotation-plus-scale map is the representation-level analogue: it carries the part of one modality's signal that the other can also receive, and drops the rest. The section on transducers as wavelength-matched antennas gives the physical conditions.

MEMS PMUT and CMUT. Micromachined ultrasonic transducers are the clearest case of physics designing the interface: membrane diameter and thickness set resonance, a light membrane matches air's impedance better than bulk ceramic, and arrays at λ/2 pitch beam-steer as RF patch arrays do. The same array mathematics (delays, apertures, grating lobes) applies to both, which is one reason to expect shared spatial structure between RF and acoustic sensors.

Classic acoustic–electrical and EM analogies. The impedance analogy table maps pressure, force and E-field onto voltage, and volume velocity, velocity and H-field onto current, with matching storage and loss elements. Engineers have long designed loudspeakers, microphones and ultrasonic matching layers as electrical circuits through these analogies. A learned rotation and scale between sensor representations would be a data-driven cousin of the same idea; whether it holds for sensors is what the test plan is for.

The 13 families are also laid out as coverage zones in the sensor room, with a 2D floor plan and an optional 3D view.