5 classes on power and electricity: metering, power quality, node telemetry, emission signatures and battery state.

Overview

Power & electrical has 5 classes: current / energy metering (CT, smart meter), power quality / waveform capture at kHz, node / board telemetry (power draw, thermals), EMI / RF emission signatures and battery / BMS state. The family watches both the loads in a space and the sensing nodes themselves, so it is a modality (which equipment is running) and a health input for the rest of the grid.

5 classes · 1 circuit card · Requirements grid for this family · Sensor room zone

What it senses

  • Which equipment is running and how much it draws.
  • Waveform quality at kHz rates.
  • The health of the sensing nodes themselves.

Modalities in this family

5 classes, grouped by physics. Open the requirements grid for bandwidth, data rate, link tier and the other views.

Propagating EM (RF to THz) 1

Key physics

  • Flux and conjugate pair: Electrical power P = V·I, with voltage and current as the conjugate pair; CTs use Faraday induction V = −dΦ/dt; EMI adds conducted V·I and radiated S = E × H.
  • Characteristic scale: Line frequency 50/60 Hz; the 50th harmonic needs sampling above ~6 kHz; shunts in mΩ; EMC bands 150 kHz–6 GHz (λ = 2 km–5 cm).
  • Resonance / aperture condition: Input matching, isolation and anti-alias filtering with bandwidth ≫ the harmonics; CT core and burden set the passband (a Rogowski coil needs an integrator); EMI near-field probes are ≪ λ and read E or H separately.

In the shared space: the hypothesis is that V·I fits the same conjugate-pair structure as p·v and E·H (the impedance analogy), giving power signals a defined place in the map, while board telemetry acts as a common-cause term rather than a sensed signal. Not measured.

Strengths and limits

Strengths

  • Both a modality (which loads are active) and a health input for the rest of the grid.
  • Electrical signals are easy to timestamp and cross-check.

Limits

  • Mains-related pickup can contaminate other channels, a common cause to watch.
  • Metering hardware and safety constraints vary by site.

Front-end circuits

Open questions for the symposium

  • How should node power and thermals feed the health verdict?
  • Which electrical signatures are reliable enough to count as evidence?

Symposium room. Planned room: PWR. See the plan and the run of show. Room sessions are marked Coming; no results exist yet.

Source data

Datasets, standards, tools and datasheets recorded for this family. Browse all sources for this family.

Parts in the Cog Explorer

Parts in the Cog Explorer. 0 in the catalog, 6 proposed (pending review), of 6 named parts. See coverage for this family. Open a named part, or browse the WeftOS Cog Explorer.

  • ADE9000 proposed (pending review)
  • ADE7953 proposed (pending review)
  • SCT-013-000 proposed (pending review)
  • INA228 proposed (pending review)
  • MAX17048 proposed (pending review)
  • BQ34Z100-G1 proposed (pending review)

Update log

  • v3 Family page created with overview, modalities, physics, strengths and limits, open questions and this log.