Power quality / waveform (kHz)
Power quality / waveform (kHz) — a Possible class in Power & electrical. Sources, example devices and what it measures.
What it measures
Power & electricalPossibleElectrical power and biopotential
This class sits in the Power & electrical coverage zone of the schematic sensor room. The zone is a layout, not measured coverage.
Front-end circuit: 26 · Current transformer with burden resistor.
In the grid. Power & electrical.
Physics. P = V·I; harmonics up to kHz
Characteristic scale. sampling ≥ 2× harmonic order × 50/60 Hz (> 5 kHz at 50 Hz, > 6 kHz at 60 Hz for the 50th harmonic); 16-bit ADC (typ.)
Resonance or aperture. anti-alias filter and isolation; sensor bandwidth ≫ harmonics
- Rate1-50 kS/s
- Bandwidth10-200 kB/s
- Link tierEthernet 1G
- ComputeFFT
- Can run onMCU, SBC
- Reachneeds new link
Sources
REDD / UK-DALE energy disaggregation datasets
Mains + appliance power, kHz waveforms (UK-DALE) for pw1/pw2/pw4
ADI ADE9000 datasheet (power quality, waveform buffer 32 kSPS)
Waveform capture, harmonics, dip/swell
IEC 61000-4-30 Power quality measurement methods
Class A/S measurement definitions for pw2
Devices
- ADE9000Analog Devicespower-quality metering ICproposed (pending review)Datasheet
Open questions for the symposium
These are the open questions for the Power & electrical family, which this class belongs to.
- How should node power and thermals feed the health verdict?
- Which electrical signatures are reliable enough to count as evidence?