Environmental
Environmental: 8 stream classes, with eight grid views.
Environmental: physics in brief
Environmental has 8 classes that measure the air, water and ground around a node, mostly slowly. The core is diffusive or chemical rather than wave physics: temperature / humidity / pressure, VOC / MOX gas and electrochemical gas sensors. The rest borrow physics: CO2 (NDIR) and particulates are optical, radiation / radon is ionizing counting, and water leak / soil moisture is quasi-static capacitance.
- Flux and conjugate pair: Heat flux q = −k∇T (temperature and entropy flux as the pair); mass flux J = −D∇c (concentration and chemical potential); plus Beer–Lambert absorption for NDIR and Poisson counts for radiation.
- Characteristic scale: Time constants dominate: housed T/H sensors ~seconds, electrochemical cells ~20–60 s, MOX seconds to minutes; gas diffusivity D ~10-5 m²/s gives τ ~ L²/D; CO2 absorbs at 4.26 µm; water εr ≈ 80 against ~1 for air.
- Resonance / aperture condition: For most classes there is no wave and no antenna: the inlet, membrane, diffusion barrier or heater cycle sets the response and τ is the bandwidth limit; NDIR puts a narrow filter on the CO2 line with a reference channel.
In the shared space: the hypothesis is that these classes contribute slow context and drift terms with a large private component, since calibration gain is sensor-specific, which makes them poor candidates for a shared rotation. Not measured.
Front-end circuits for this family
- 22 Electrochemical gas sensor potentiostat serves: Electrochemical gas (CO, NO2, O3, H2S)
- 23 NTC thermistor divider serves: Temperature / humidity / pressure (temperature channel)
env-physics, env-signal, env-hardware. Planned room ENV (3 agents), chaired by env-physics; no hot cells; reviewed by the adversarial group in S2.4. Symposium plan (plan only, not launched).Environmental: requirements grid (8 classes)
8 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.
Overview
| Class | Family / band | Rate | Bandwidth | Link tier | Maturity | Provenance |
|---|---|---|---|---|---|---|
| Temperature / humidity / pressure | Environmental | 0.01-1 Hz | bytes/min | MCU bus | prototyped | repo |
| CO2 (NDIR) | Environmental (also EM: IR) | 1/60 Hz | bytes/min | MCU bus | tested | repo |
| Particulates (PM1/2.5/10) | Environmental | 1/s-1/min | bytes/s | MCU bus | possible | typical |
| VOC / MOX gas | Environmental | 0.1-1 Hz | bytes/s | MCU bus | identified | repo |
| Electrochemical gas (CO, NO2, O3, H2S) | Environmental | 0.1-1 Hz | bytes/s | Field bus | possible | typical |
| Radiation / radon | Environmental (also EM: gamma) | counts/min | bytes/min | MCU bus | possible | typical |
| Water leak / level / soil moisture | Environmental | events-1/min | bytes | Wireless | possible | typical |
| Weather (wind, rain, solar) | Environmental | 1 Hz-1/min | bytes/s | Field bus | possible | typical |
Timing & bandwidth
| Class | Family / band | Examples | Rate | Bandwidth | Tier | Latency | Jitter | Sync |
|---|---|---|---|---|---|---|---|---|
| Temperature / humidity / pressure | Environmental | BME280, BME680 (catalog) | 0.01-1 Hz | bytes/min | T0 trickle | min | s | s |
| CO2 (NDIR) | Environmental (also EM: IR) | edge-node pack CO2 every 60 s | 1/60 Hz | bytes/min | T0 trickle | min | s | s |
| Particulates (PM1/2.5/10) | Environmental | none yet | 1/s-1/min | bytes/s | T0 trickle | min | s | s |
| VOC / MOX gas | Environmental | BME680 (catalog) | 0.1-1 Hz | bytes/s | T0 trickle | min | s | s |
| Electrochemical gas (CO, NO2, O3, H2S) | Environmental | none yet | 0.1-1 Hz | bytes/s | T0 trickle | s-min | s | s |
| Radiation / radon | Environmental (also EM: gamma) | none yet | counts/min | bytes/min | T0 trickle | min-h | s | s |
| Water leak / level / soil moisture | Environmental | none yet | events-1/min | bytes | T0 trickle | s | s | s |
| Weather (wind, rain, solar) | Environmental | none yet | 1 Hz-1/min | bytes/s | T0 trickle | min | s | s |
Compute & storage
| Class | Compute | Can run on | Memory | Storage | Power |
|---|---|---|---|---|---|
| Temperature / humidity / pressure | none | MCU | bytes | years | uW |
| CO2 (NDIR) | none | MCU | bytes | years | <0.1 W |
| Particulates (PM1/2.5/10) | none | MCU | bytes | long | 0.1-0.5 W |
| VOC / MOX gas | baseline algorithm | MCU | KB | long | mW |
| Electrochemical gas (CO, NO2, O3, H2S) | none | MCU | bytes | long | mW |
| Radiation / radon | none | MCU | bytes | long | mW |
| Water leak / level / soil moisture | none | MCU | bytes | events | uW |
| Weather (wind, rain, solar) | none | MCU | bytes | long | mW |
Link & mesh
| Class | Transport | Link tier | Reach | Unit | Mesh status |
|---|---|---|---|---|---|
| Temperature / humidity / pressure | I2C | MCU bus | reachable now | source | schema + vectors |
| CO2 (NDIR) | UART, I2C | MCU bus | reachable now | source | schema + vectors |
| Particulates (PM1/2.5/10) | UART | MCU bus | reachable now | source | nothing yet |
| VOC / MOX gas | I2C | MCU bus | reachable now | source | nothing yet |
| Electrochemical gas (CO, NO2, O3, H2S) | I2C, 4-20 mA | Field bus | reachable now | source | nothing yet |
| Radiation / radon | GPIO | MCU bus | reachable now | source | nothing yet |
| Water leak / level / soil moisture | GPIO, LoRa | Wireless | reachable now | source | nothing yet |
| Weather (wind, rain, solar) | RS-485, LoRa | Field bus | reachable now | source | nothing yet |
Physics & health
| Class | Env. sensitivity | Calibration | Failure signature | Cross-check | Common cause | EM-acoustic crossover |
|---|---|---|---|---|---|---|
| Temperature / humidity / pressure | self-heating | reference | stuck value | neighbor nodes | enclosure, HVAC | none identified |
| CO2 (NDIR) | airflow | ABC baseline | ABC drift | occupancy | HVAC | photoacoustic NDIR variants; partner em24 |
| Particulates (PM1/2.5/10) | humidity | reference | fan failure | neighbors | HVAC | none identified |
| VOC / MOX gas | humidity | burn-in | poisoning | CO2 | HVAC | none identified |
| Electrochemical gas (CO, NO2, O3, H2S) | temperature | bump test | cell aging | redundant cell | area | none identified |
| Radiation / radon | background | source | zero counts | neighbors | site | none identified |
| Water leak / level / soil moisture | corrosion | none | open circuit | none | location | none identified |
| Weather (wind, rain, solar) | icing | reference | stuck anemometer | public feeds | mast | none identified |
Physics & flux
Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).
| Class | Physics group | Conjugate pair / energy flux | Characteristic scale | Resonance / aperture ("antenna") condition | Shared-space hook (rotation, scale, phase gate) |
|---|---|---|---|---|---|
| Temperature / humidity / pressure | THR Thermal conduction and IR emission | heat flux q = −k∇T (temperature); capacitive humidity; diaphragm pressure p | sensor τ ~ seconds (typ., with housing); self-heating error; thermal mass vs. airflow | no wave: thermal time constant τ is the bandwidth limit; keep the sensor thermally isolated from board heat; pressure diaphragm resonance sits far above band | R: T and entropy-flux axes. s: effusivity and τ. Phase gate: the thermal low-pass, whose phase lag is predictable and modelled. |
| CO2 (NDIR) | OPT Optical / infrared photons | Beer–Lambert absorption at 4.26 µm (CO2 band) | λ = 4.26 µm; path length ~ cm; thermopile detector τ ~ 10s of ms | IR source + narrow bandpass filter on the CO2 line (resonance) and a reference channel (3.9 µm); optical cavity length L ≫ λ | R: polarisation and image-plane axes. s: Z0/n and photon energy hc/λ. Phase gate: coherence or a lock-in reference; ordinary cameras discard phase. |
| Particulates (PM1/2.5/10) | OPT Optical / infrared photons | light scattering (Mie) from particles; photodiode current | λ ≈ 650–780 nm laser; particle sizes 0.3–10 µm ~ λ (Mie regime) | laser + photodiode geometry fixes the scattering angle; airflow (fan) sets sample volume | R: polarisation and image-plane axes. s: Z0/n and photon energy hc/λ. Phase gate: coherence or a lock-in reference; ordinary cameras discard phase. |
| VOC / MOX gas | CHM Chemical and particulate transport | surface reaction on a heated oxide (conductance G); mass flux J = −D∇c | heater 200–400 °C; τ ~ seconds–minutes; baseline drift | heater cycle (temperature modulation) provides selectivity; no wave: response time is the bandwidth | R: species axes. s: calibration gain (sensor-specific). Phase gate: sampling lag and drift are private to the modality. |
| Electrochemical gas (CO, NO2, O3, H2S) | CHM Chemical and particulate transport | Faradaic current i ∝ concentration (electrons carry charge: V·I at the electrode) | sensitivity nA/ppm (typ.); τ ~ 20–60 s; cross-sensitivity | diffusion barrier and electrolyte volume set response; periodic zero and span calibration | R: species axes. s: calibration gain (sensor-specific). Phase gate: sampling lag and drift are private to the modality. |
| Radiation / radon | ION Ionizing radiation (X-ray, gamma) | radiation counting (alpha/gamma); Poisson statistics | count rate per µSv/h (tube-specific); radon progeny alpha energies ~MeV | tube or diode window thickness sets which radiation counts; diffusion chamber for radon | R: spectral energy bins and direction. s: counts per unit flux and efficiency. Phase gate: n/a, counts only. |
| Water leak / level / soil moisture | EMQ Quasi-static / near-field EM | quasi-static E-field: capacitance or resistance changes with water (εr ≈ 80 vs. ~1 for air) | εr(water) ≈ 80; soil dielectric 3–40 (typ.); FDR/capacitance probes ~10–150 MHz; TDR uses sub-ns steps (~GHz content) | electrodes ≪ λ; probe geometry sets sensed volume; for TDR the rod length is a transmission-line delay | R: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private. |
| Weather (wind, rain, solar) | MIX Composite or multi-physics | ultrasonic anemometer: acoustic time of flight (p·v); rain tip/impact (F·v); pyranometer: radiant flux | c ≈ 343 m/s ± wind speed; solar irradiance ~1 kW/m² clear-sky peak at ground | ultrasonic paths ~10 cm (transducers ~tens to ~200 kHz, typ.); thermopile pyranometer dome (diffuser) for 0.3–3 µm | Split into its component modalities before mapping; each part uses its own group. |
Scale
| Class | Room x10 | Building x300 | Factory x5000 | Compute at factory | Scale note |
|---|---|---|---|---|---|
| Temperature / humidity / pressure | 3.2 B/s | 95 B/s | 1.6 kB/s | central is fine | population baseline per floor |
| CO2 (NDIR) | 3.2 B/s | 95 B/s | 1.6 kB/s | central is fine | same as building |
| Particulates (PM1/2.5/10) | 10 B/s | 300 B/s | 5 kB/s | central is fine | same as building |
| VOC / MOX gas | 10 B/s | 300 B/s | 5 kB/s | central is fine | same as building |
| Electrochemical gas (CO, NO2, O3, H2S) | 10 B/s | 300 B/s | 5 kB/s | central is fine | safety-rated at factory |
| Radiation / radon | 1 B/s | 30 B/s | 500 B/s | central is fine | same as building |
| Water leak / level / soil moisture | 1 B/s | 30 B/s | 500 B/s | central is fine | same as building |
| Weather (wind, rain, solar) | 10 B/s | 300 B/s | 5 kB/s | central is fine | same as building |
Governance
| Class | Maturity | Privacy | Provenance |
|---|---|---|---|
| Temperature / humidity / pressure | prototyped | low | project notes: module types note environmental; senml.v1 |
| CO2 (NDIR) | tested | low | project notes: edge node inventory note |
| Particulates (PM1/2.5/10) | possible | low | typical |
| VOC / MOX gas | identified | low | project notes: module types note |
| Electrochemical gas (CO, NO2, O3, H2S) | possible | low | typical |
| Radiation / radon | possible | low | typical |
| Water leak / level / soil moisture | possible | low | typical |
| Weather (wind, rain, solar) | possible | low | typical |