Contact & physical has 5 classes that read contact, load and state directly: pressure mat / FSR, load cell / strain gauge, door / reed / limit switch, capacitive proximity / touch, and flow / level / position encoders. They are the simplest sensors in the grid and often the most trusted, because a switch or a load cell leaves little room for interpretation, which makes them useful ground truth for the richer classes.
Flux and conjugate pair: Mostly F·v (force and velocity; stress and strain rate), converted to V·I by a bridge or resistive element; capacitive and reed sensing use quasi-static E or H fields.
Characteristic scale: Contact pressure kPa–MPa; strain-gauge factor ≈ 2 with ~2 mV/V at full scale (typ.); capacitance ~pF with fF changes; reed thresholds ~a few mT (typ.).
Resonance / aperture condition: Quasi-static, so no wave: compliance, electrode or magnet geometry is the aperture; a mechanical resonance f0 = (1/2π)√(k/m) bounds load-cell bandwidth; switches need ~ms debounce.
In the shared space: the hypothesis is that these low-dimensional, near-binary signals act as anchor labels for fitting and checking maps rather than as embeddings to be rotated. Not measured.
The same lumped network in four domains (impedance analogy).
Symposium rooms. Planned room: PHY. Context pack: PHY. Experts: phy-physics, phy-signal. Planned room PHY (2 agents), chaired by phy-physics; hot cells with MATH in S3.1; reviewed by the adversarial group in S2.4. Symposium plan (plan only, not launched).
Contact & physical: requirements grid (5 classes)
5 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.
Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).
magnetic reed: H·B closes a switch; limit switch: contact force
operate field of order mT (reed switches are rated in ampere-turns, typ.); no signal bandwidth
sensor ≪ λ; contact debounce time ~ ms; magnet gap sets threshold
R: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.
R: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.