Omni Modal Sensor Symposium

Contact & physical

Family view: Contact & physical (5 classes).

Contact & physical: physics in brief

Contact & physical has 5 classes that read contact, load and state directly: pressure mat / FSR, load cell / strain gauge, door / reed / limit switch, capacitive proximity / touch, and flow / level / position encoders. They are the simplest sensors in the grid and often the most trusted, because a switch or a load cell leaves little room for interpretation, which makes them useful ground truth for the richer classes.

  • Flux and conjugate pair: Mostly F·v (force and velocity; stress and strain rate), converted to V·I by a bridge or resistive element; capacitive and reed sensing use quasi-static E or H fields.
  • Characteristic scale: Contact pressure kPa–MPa; strain-gauge factor ≈ 2 with ~2 mV/V at full scale (typ.); capacitance ~pF with fF changes; reed thresholds ~a few mT (typ.).
  • Resonance / aperture condition: Quasi-static, so no wave: compliance, electrode or magnet geometry is the aperture; a mechanical resonance f0 = (1/2π)√(k/m) bounds load-cell bandwidth; switches need ~ms debounce.

In the shared space: the hypothesis is that these low-dimensional, near-binary signals act as anchor labels for fitting and checking maps rather than as embeddings to be rotated. Not measured.

Impedance analogies: one series loop drawn four ways Four panels show the same series loop with a source, a resistance, an inertance and a capacitance. Electrical: V, R, L, C, current I. Acoustic: pressure p, acoustic resistance, acoustic mass (like inductance), compliance (like capacitance), volume velocity U (like current). Mechanical, impedance analogy: force F like voltage, velocity v like current, mass like inductance, compliance 1/k like capacitance, damping like resistance. Thermal: temperature difference like voltage, heat flow like current, thermal resistance and heat capacity only, no inductance, so it is diffusive and never resonates. Dots on the bottom wire show the flow: oscillating in the first three, decaying one way in the thermal loop. Electrical Z = R + jωL + 1/(jωC) V R L C I (current) effort: voltage V flow: current I inertance: inductance L storage: capacitance C loss: resistance R resonance ω0 = 1/√(LC) Acoustic (impedance analogy) Za = p/U (Pa·s/m³); p·U in W p Ra Ma Ca U (volume velocity) pressure p ↔ voltage V volume velocity U ↔ current I acoustic mass Ma ↔ inductance L compliance Ca ↔ capacitance C acoustic resistance Ra ↔ R ω0 = 1/√(MaCa) (Helmholtz) Mechanical (impedance analogy) Zm = F/v (N·s/m); F·v in W F Rm m 1/k v (velocity) force F ↔ voltage V velocity v ↔ current I mass m ↔ inductance L compliance 1/k ↔ capacitance C damping Rm ↔ R ω0 = √(k/m) Thermal diffusive: RC only, no resonance ΔT Rth (no inductor) Cth q (heat flow, W) temperature ΔT ↔ voltage V heat flow q ↔ current I heat capacity Cth ↔ C thermal resistance Rth ↔ R no thermal inductance: τ = Rth·Cth, decays, never rings
The same lumped network in four domains (impedance analogy).

Front-end circuits for this family

Contact & physical: requirements grid (5 classes)

5 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.

Overview

ClassFamily / bandRateBandwidthLink tierMaturityProvenance
Pressure mat / FSRContact & physical10-100 Hz<10 kB/sMCU buspossibletypical
Load cell / strain gaugeContact & physical10 Hz-1 kHz<10 kB/sMCU buspossibletypical
Door / reed / limit switchContact & physicaleventsbytesMCU buspossibletypical
Capacitive proximity / touchContact & physical10-100 Hz<1 kB/sMCU busprototypedrepo
Flow / level / position encodersContact & physical1 Hz-10 kHzbytes-kB/sField buspossibletypical

Timing & bandwidth

ClassFamily / bandExamplesRateBandwidthTierLatencyJitterSync
Pressure mat / FSRContact & physicalnone yet10-100 Hz<10 kB/sT1 10 B-10 kB/s0.1 smss
Load cell / strain gaugeContact & physicalnone yet10 Hz-1 kHz<10 kB/sT1 10 B-10 kB/sms-smsms
Door / reed / limit switchContact & physicalnone yeteventsbytesT0 tricklems-sss
Capacitive proximity / touchContact & physicalGT911 touch (weftos-leaf-touch-gt911)10-100 Hz<1 kB/sT1 10 B-10 kB/s10-50 msmss
Flow / level / position encodersContact & physicalnone yet1 Hz-10 kHzbytes-kB/sT1 10 B-10 kB/sms-smsms

Compute & storage

ClassComputeCan run onMemoryStoragePower
Pressure mat / FSRlightMCUKBeventsmW
Load cell / strain gaugenoneMCUKBlongmW
Door / reed / limit switchnoneMCUbyteseventsuW
Capacitive proximity / touchnoneMCUbyteseventsmW
Flow / level / position encodersnoneMCU, PLCbyteslongmW-W

Link & mesh

ClassTransportLink tierReachUnitMesh status
Pressure mat / FSRADCMCU busreachable nowsourcenothing yet
Load cell / strain gaugeADC (HX711)MCU busreachable nowsourcenothing yet
Door / reed / limit switchGPIO, ZigbeeMCU busreachable nowsourcenothing yet
Capacitive proximity / touchI2CMCU busreachable nowsourcenothing yet
Flow / level / position encoders4-20 mA, ModbusField busreachable nowsourcenothing yet

Physics & health

ClassEnv. sensitivityCalibrationFailure signatureCross-checkCommon causeEM-acoustic crossover
Pressure mat / FSRcreepzerocreepradar vitalslocationnone identified
Load cell / strain gaugetemperaturespancreep, driftFBGstructurenone identified
Door / reed / limit switchalignmentnonechattercamera, radardoornone identified
Capacitive proximity / touchhumiditybaselinebaseline driftcamerapanelnone identified
Flow / level / position encodersfoulingmeter factorstuck readingredundant meterprocess linemagnetostrictive level and position sensors

Physics & flux

Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).

ClassPhysics groupConjugate pair / energy fluxCharacteristic scaleResonance / aperture ("antenna") conditionShared-space hook (rotation, scale, phase gate)
Pressure mat / FSRSOL Solid-borne vibration, force, inertiaforce F and displacement x (power F·v); piezoresistive FSRkPa–MPa contact pressure; hysteresis and drift (FSR ~10 %, typ.)quasi-static: no wave; contact compliance and electrode geometry set the aperture; scan-matrix settling timeR: F/v pair and the sensing axis. s: mass or stiffness and Z. Phase gate: stay below f0 (or model it), so the output follows real motion.
Load cell / strain gaugeSOL Solid-borne vibration, force, inertiastress·strain (power F·v); Wheatstone bridge converts strain ε to ΔV (V·I)gauge factor ≈ 2; sensitivity ~2 mV/V at full scale (typ.); mechanical resonance f0 = (1/2π)√(k/m)bridge excitation and low-noise amp; f0 sets bandwidth; temperature compensationR: F/v pair and the sensing axis. s: mass or stiffness and Z. Phase gate: stay below f0 (or model it), so the output follows real motion.
Door / reed / limit switchEMQ Quasi-static / near-field EMmagnetic reed: H·B closes a switch; limit switch: contact forceoperate field of order mT (reed switches are rated in ampere-turns, typ.); no signal bandwidthsensor ≪ λ; contact debounce time ~ ms; magnet gap sets thresholdR: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.
Capacitive proximity / touchEMQ Quasi-static / near-field EMquasi-static E-field: displacement current through a fringing capacitance (V·I)C ~ pF; ΔC ~ fF; ε0, εr of the targetelectrode size ~ sensing distance (≪ λ); guard electrode shapes the field; excitation 10 kHz–1 MHzR: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.
Flow / level / position encodersMIX Composite or multi-physicsflow: Δp or ultrasonic transit time; level: acoustic/radar time of flight; encoder: optical or magnetic phaseranges metres; time of flight c·t/2; encoder PPRdepends on principle; ultrasonic and radar level sensors need beam aperture ≳ λ and a clean near-field (blanking zone)Split into its component modalities before mapping; each part uses its own group.

Scale

ClassRoom x10Building x300Factory x5000Compute at factoryScale note
Pressure mat / FSR10 kB/s300 kB/s5 MB/sedge aggregator per floorsame as building
Load cell / strain gauge10 kB/s300 kB/s5 MB/sedge aggregator per floorsame as building
Door / reed / limit switch<1 B/s9.5 B/s158 B/scentral is finesame as building
Capacitive proximity / touch3.2 kB/s95 kB/s1.6 MB/sedge aggregator per floorsame as building
Flow / level / position encoders1 kB/s30 kB/s500 kB/scentral is finesame as building

Governance

ClassMaturityPrivacyProvenance
Pressure mat / FSRpossiblemediumtypical
Load cell / strain gaugepossiblelowtypical
Door / reed / limit switchpossiblelowtypical
Capacitive proximity / touchprototypedlowproject notes: the weftos-leaf-touch-gt911 crate
Flow / level / position encoderspossiblelowtypical