Industrial & machine has 3 classes: CAN / CAN-FD bus signals, PLC tags (Modbus, OPC-UA) and motor drive / spindle telemetry. Two of the three are already digital: the machine has done the sensing and publishes values, so what matters is the bus and the scan cycle. Motor-drive telemetry still carries real physics: phase currents, spindle torque and vibration.
Flux and conjugate pair: Bus classes: differential V·I on a transmission line carrying bits, with no sensed flux; drives: electrical V·I, mechanical τ·ω at the spindle and vibration F·v.
Characteristic scale: CAN twisted pair Z0 ≈ 120 Ω, CAN-FD to ~5–8 Mb/s, ~40 m at 1 Mb/s; Ethernet 100 Ω differential, RS-485 120 Ω; drive PWM ~4–16 kHz (typ.).
Resonance / aperture condition: Terminate both bus ends at the line impedance so the signal propagates without reflections, and keep stubs short; drive current sensors need bandwidth above the PWM harmonics, and mechanical resonance limits what is observable.
In the shared space: the hypothesis is that bus values enter the ring as already-labelled time series (an embedding plus a scan-cycle timestamp), while drive telemetry can be mapped alongside the vibration and power classes. Not measured.
The same lumped network in four domains (impedance analogy).
Symposium rooms. Planned room: IND. Context pack: IND. Experts: ind-physics, ind-signal. Planned room IND (2 agents), chaired by ind-physics; no hot cells; reviewed by the adversarial group in S2.4. Symposium plan (plan only, not launched).
3 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.
Overview
Class
Family / band
Rate
Bandwidth
Link tier
Maturity
Provenance
CAN / CAN-FD bus signals
Industrial & machine
100-10k frames/s
10-500 kB/s
Field bus
prototyped
repo
PLC tags (Modbus, OPC-UA)
Industrial & machine
0.1-100 Hz
kB/s per PLC
Ethernet 1G
possible
typical
Motor drive / spindle telemetry
Industrial & machine
1 Hz-10 kHz
kB-MB/s
Ethernet 1G
possible
typical
Timing & bandwidth
Class
Family / band
Examples
Rate
Bandwidth
Tier
Latency
Jitter
Sync
CAN / CAN-FD bus signals
Industrial & machine
can-fd, can-anomaly cogs (plan P7)
100-10k frames/s
10-500 kB/s
T2 10 kB-1 MB/s
ms
ms
no time in CAN payload
PLC tags (Modbus, OPC-UA)
Industrial & machine
none yet
0.1-100 Hz
kB/s per PLC
T1 10 B-10 kB/s
10 ms-s
ms
PTP/NTP
Motor drive / spindle telemetry
Industrial & machine
none yet
1 Hz-10 kHz
kB-MB/s
T2 10 kB-1 MB/s
ms
µs
µs (EtherCAT DC)
Compute & storage
Class
Compute
Can run on
Memory
Storage
Power
CAN / CAN-FD bus signals
decode, anomaly
MCU, SBC
KB
decoded signals
self
PLC tags (Modbus, OPC-UA)
none
edge gateway
KB
historian
n/a
Motor drive / spindle telemetry
edge ML
edge
MBs
features
n/a
Link & mesh
Class
Transport
Link tier
Reach
Unit
Mesh status
CAN / CAN-FD bus signals
CAN
Field bus
reachable now
source+processor
schema + vectors
PLC tags (Modbus, OPC-UA)
Ethernet
Ethernet 1G
needs new link
source
nothing yet
Motor drive / spindle telemetry
EtherCAT, PROFINET
Ethernet 1G
needs new link
source
nothing yet
Physics & health
Class
Env. sensitivity
Calibration
Failure signature
Cross-check
Common cause
EM-acoustic crossover
CAN / CAN-FD bus signals
EMI
DBC files
bus-off, error frames
physical sensors
bus
none identified
PLC tags (Modbus, OPC-UA)
none
tag map
stale tags
physical sensors
PLC
none identified
Motor drive / spindle telemetry
load
commissioning
alarms
vibration, current
drive
motor current, vibration and magnetic field; partners ac7, im2
Physics & flux
Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).
Class
Physics group
Conjugate pair / energy flux
Characteristic scale
Resonance / aperture ("antenna") condition
Shared-space hook (rotation, scale, phase gate)
CAN / CAN-FD bus signals
DIGDigital, timing and derived
differential V·I on a transmission line; frames carry bits
twisted pair Z0 ≈ 120 Ω; CAN-FD to 5–8 Mb/s; ~40 m at 1 Mb/s
terminate both ends with 120 Ω (no reflections = real propagating signal); stubs kept short (~0.3 m at 1 Mb/s, typ.)
Not a sensing physics. Enters the ring only as an embedding or a time label; its health is the clock and link, not the field.