Omni Modal Sensor SymposiumOmni Modal
Cog Explorer

Environmental

Environmental: 8 stream classes, with eight grid views.

Environmental: physics in brief

Environmental has 8 classes that measure the air, water and ground around a node, mostly slowly. The core is diffusive or chemical rather than wave physics: temperature / humidity / pressure, VOC / MOX gas and electrochemical gas sensors. The rest borrow physics: CO2 (NDIR) and particulates are optical, radiation / radon is ionizing counting, and water leak / soil moisture is quasi-static capacitance.

  • Flux and conjugate pair: Heat flux q = −k∇T (temperature and entropy flux as the pair); mass flux J = −D∇c (concentration and chemical potential); plus Beer–Lambert absorption for NDIR and Poisson counts for radiation.
  • Characteristic scale: Time constants dominate: housed T/H sensors ~seconds, electrochemical cells ~20–60 s, MOX seconds to minutes; gas diffusivity D ~10-5 m²/s gives τ ~ L²/D; CO2 absorbs at 4.26 µm; water εr ≈ 80 against ~1 for air.
  • Resonance / aperture condition: For most classes there is no wave and no antenna: the inlet, membrane, diffusion barrier or heater cycle sets the response and τ is the bandwidth limit; NDIR puts a narrow filter on the CO2 line with a reference channel.

In the shared space: the hypothesis is that these classes contribute slow context and drift terms with a large private component, since calibration gain is sensor-specific, which makes them poor candidates for a shared rotation. Not measured.

Flux vectors in three kinds of physics: EM, acoustic and thermal diffusion Three panels. EM: E and H oscillate together and S = E x H always points along travel. Acoustic: pressure p and particle velocity v oscillate together and I = p v always points along travel. Thermal: a temperature step relaxes by diffusion; the profile spreads, the heat flux q = -k grad T shrinks, and nothing oscillates: diffusive, no propagating phase. Bottom row: the conjugate effort-flow pair whose product is the power flux in each case. Electromagnetic S = E × H (Poynting vector) E H (out of page) S E and H flip together, so S never reverses Acoustic I = p·v (sound intensity) p v (along travel) I p and v flip together, so I never reverses Thermal diffusion q = −k∇T (Fourier's law) hot x T(x) q (shrinks as ∇T relaxes) diffusive: no propagating phase profile spreads ~ √(αt); nothing oscillates Conjugate pairs (effort × flow = power flux): E (V/m) × H (A/m) → S (W/m²) wave: propagating phase, c ≈ 3×108 m/s p (Pa) × v (m/s) → I (W/m²) wave: propagating phase, c ≈ 343 m/s (air) T (K) × q/T (W/(m²·K)) → q (W/m²) diffusion: ∂T/∂t = α∇²T, no wave speed
Energy flux and its conjugate pair in EM, acoustic and thermal transport. Thermal transport is diffusive and has no propagating phase.

Front-end circuits for this family

Environmental: requirements grid (8 classes)

8 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.

Overview

ClassFamily / bandRateBandwidthLink tierMaturityProvenance
Temperature / humidity / pressureEnvironmental0.01-1 Hzbytes/minMCU busprototypedrepo
CO2 (NDIR)Environmental (also EM: IR)1/60 Hzbytes/minMCU bustestedrepo
Particulates (PM1/2.5/10)Environmental1/s-1/minbytes/sMCU buspossibletypical
VOC / MOX gasEnvironmental0.1-1 Hzbytes/sMCU busidentifiedrepo
Electrochemical gas (CO, NO2, O3, H2S)Environmental0.1-1 Hzbytes/sField buspossibletypical
Radiation / radonEnvironmental (also EM: gamma)counts/minbytes/minMCU buspossibletypical
Water leak / level / soil moistureEnvironmentalevents-1/minbytesWirelesspossibletypical
Weather (wind, rain, solar)Environmental1 Hz-1/minbytes/sField buspossibletypical

Timing & bandwidth

ClassFamily / bandExamplesRateBandwidthTierLatencyJitterSync
Temperature / humidity / pressureEnvironmentalBME280, BME680 (catalog)0.01-1 Hzbytes/minT0 trickleminss
CO2 (NDIR)Environmental (also EM: IR)edge-node pack CO2 every 60 s1/60 Hzbytes/minT0 trickleminss
Particulates (PM1/2.5/10)Environmentalnone yet1/s-1/minbytes/sT0 trickleminss
VOC / MOX gasEnvironmentalBME680 (catalog)0.1-1 Hzbytes/sT0 trickleminss
Electrochemical gas (CO, NO2, O3, H2S)Environmentalnone yet0.1-1 Hzbytes/sT0 trickles-minss
Radiation / radonEnvironmental (also EM: gamma)none yetcounts/minbytes/minT0 tricklemin-hss
Water leak / level / soil moistureEnvironmentalnone yetevents-1/minbytesT0 tricklesss
Weather (wind, rain, solar)Environmentalnone yet1 Hz-1/minbytes/sT0 trickleminss

Compute & storage

ClassComputeCan run onMemoryStoragePower
Temperature / humidity / pressurenoneMCUbytesyearsuW
CO2 (NDIR)noneMCUbytesyears<0.1 W
Particulates (PM1/2.5/10)noneMCUbyteslong0.1-0.5 W
VOC / MOX gasbaseline algorithmMCUKBlongmW
Electrochemical gas (CO, NO2, O3, H2S)noneMCUbyteslongmW
Radiation / radonnoneMCUbyteslongmW
Water leak / level / soil moisturenoneMCUbyteseventsuW
Weather (wind, rain, solar)noneMCUbyteslongmW

Link & mesh

ClassTransportLink tierReachUnitMesh status
Temperature / humidity / pressureI2CMCU busreachable nowsourceschema + vectors
CO2 (NDIR)UART, I2CMCU busreachable nowsourceschema + vectors
Particulates (PM1/2.5/10)UARTMCU busreachable nowsourcenothing yet
VOC / MOX gasI2CMCU busreachable nowsourcenothing yet
Electrochemical gas (CO, NO2, O3, H2S)I2C, 4-20 mAField busreachable nowsourcenothing yet
Radiation / radonGPIOMCU busreachable nowsourcenothing yet
Water leak / level / soil moistureGPIO, LoRaWirelessreachable nowsourcenothing yet
Weather (wind, rain, solar)RS-485, LoRaField busreachable nowsourcenothing yet

Physics & health

ClassEnv. sensitivityCalibrationFailure signatureCross-checkCommon causeEM-acoustic crossover
Temperature / humidity / pressureself-heatingreferencestuck valueneighbor nodesenclosure, HVACnone identified
CO2 (NDIR)airflowABC baselineABC driftoccupancyHVACphotoacoustic NDIR variants; partner em24
Particulates (PM1/2.5/10)humidityreferencefan failureneighborsHVACnone identified
VOC / MOX gashumidityburn-inpoisoningCO2HVACnone identified
Electrochemical gas (CO, NO2, O3, H2S)temperaturebump testcell agingredundant cellareanone identified
Radiation / radonbackgroundsourcezero countsneighborssitenone identified
Water leak / level / soil moisturecorrosionnoneopen circuitnonelocationnone identified
Weather (wind, rain, solar)icingreferencestuck anemometerpublic feedsmastnone identified

Physics & flux

Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).

ClassPhysics groupConjugate pair / energy fluxCharacteristic scaleResonance / aperture ("antenna") conditionShared-space hook (rotation, scale, phase gate)
Temperature / humidity / pressureTHR Thermal conduction and IR emissionheat flux q = −k∇T (temperature); capacitive humidity; diaphragm pressure psensor τ ~ seconds (typ., with housing); self-heating error; thermal mass vs. airflowno wave: thermal time constant τ is the bandwidth limit; keep the sensor thermally isolated from board heat; pressure diaphragm resonance sits far above bandR: T and entropy-flux axes. s: effusivity and τ. Phase gate: the thermal low-pass, whose phase lag is predictable and modelled.
CO2 (NDIR)OPT Optical / infrared photonsBeer–Lambert absorption at 4.26 µm (CO2 band)λ = 4.26 µm; path length ~ cm; thermopile detector τ ~ 10s of msIR source + narrow bandpass filter on the CO2 line (resonance) and a reference channel (3.9 µm); optical cavity length L ≫ λR: polarisation and image-plane axes. s: Z0/n and photon energy hc/λ. Phase gate: coherence or a lock-in reference; ordinary cameras discard phase.
Particulates (PM1/2.5/10)OPT Optical / infrared photonslight scattering (Mie) from particles; photodiode currentλ ≈ 650–780 nm laser; particle sizes 0.3–10 µm ~ λ (Mie regime)laser + photodiode geometry fixes the scattering angle; airflow (fan) sets sample volumeR: polarisation and image-plane axes. s: Z0/n and photon energy hc/λ. Phase gate: coherence or a lock-in reference; ordinary cameras discard phase.
VOC / MOX gasCHM Chemical and particulate transportsurface reaction on a heated oxide (conductance G); mass flux J = −D∇cheater 200–400 °C; τ ~ seconds–minutes; baseline driftheater cycle (temperature modulation) provides selectivity; no wave: response time is the bandwidthR: species axes. s: calibration gain (sensor-specific). Phase gate: sampling lag and drift are private to the modality.
Electrochemical gas (CO, NO2, O3, H2S)CHM Chemical and particulate transportFaradaic current i ∝ concentration (electrons carry charge: V·I at the electrode)sensitivity nA/ppm (typ.); τ ~ 20–60 s; cross-sensitivitydiffusion barrier and electrolyte volume set response; periodic zero and span calibrationR: species axes. s: calibration gain (sensor-specific). Phase gate: sampling lag and drift are private to the modality.
Radiation / radonION Ionizing radiation (X-ray, gamma)radiation counting (alpha/gamma); Poisson statisticscount rate per µSv/h (tube-specific); radon progeny alpha energies ~MeVtube or diode window thickness sets which radiation counts; diffusion chamber for radonR: spectral energy bins and direction. s: counts per unit flux and efficiency. Phase gate: n/a, counts only.
Water leak / level / soil moistureEMQ Quasi-static / near-field EMquasi-static E-field: capacitance or resistance changes with water (εr ≈ 80 vs. ~1 for air)εr(water) ≈ 80; soil dielectric 3–40 (typ.); FDR/capacitance probes ~10–150 MHz; TDR uses sub-ns steps (~GHz content)electrodes ≪ λ; probe geometry sets sensed volume; for TDR the rod length is a transmission-line delayR: whichever field (E or H) the transducer couples to. s: μ0/ε0 and geometry. Phase gate: only the in-phase coupled part is kept; reactive energy is private.
Weather (wind, rain, solar)MIX Composite or multi-physicsultrasonic anemometer: acoustic time of flight (p·v); rain tip/impact (F·v); pyranometer: radiant fluxc ≈ 343 m/s ± wind speed; solar irradiance ~1 kW/m² clear-sky peak at groundultrasonic paths ~10 cm (transducers ~tens to ~200 kHz, typ.); thermopile pyranometer dome (diffuser) for 0.3–3 µmSplit into its component modalities before mapping; each part uses its own group.

Scale

ClassRoom x10Building x300Factory x5000Compute at factoryScale note
Temperature / humidity / pressure3.2 B/s95 B/s1.6 kB/scentral is finepopulation baseline per floor
CO2 (NDIR)3.2 B/s95 B/s1.6 kB/scentral is finesame as building
Particulates (PM1/2.5/10)10 B/s300 B/s5 kB/scentral is finesame as building
VOC / MOX gas10 B/s300 B/s5 kB/scentral is finesame as building
Electrochemical gas (CO, NO2, O3, H2S)10 B/s300 B/s5 kB/scentral is finesafety-rated at factory
Radiation / radon1 B/s30 B/s500 B/scentral is finesame as building
Water leak / level / soil moisture1 B/s30 B/s500 B/scentral is finesame as building
Weather (wind, rain, solar)10 B/s300 B/s5 kB/scentral is finesame as building

Governance

ClassMaturityPrivacyProvenance
Temperature / humidity / pressureprototypedlowproject notes: module types note environmental; senml.v1
CO2 (NDIR)testedlowproject notes: edge node inventory note
Particulates (PM1/2.5/10)possiblelowtypical
VOC / MOX gasidentifiedlowproject notes: module types note
Electrochemical gas (CO, NO2, O3, H2S)possiblelowtypical
Radiation / radonpossiblelowtypical
Water leak / level / soil moisturepossiblelowtypical
Weather (wind, rain, solar)possiblelowtypical