Omni Modal Sensor Symposium
Cog Explorer

Bio & wearables

Bio & wearables: 4 stream classes, with eight grid views.

Bio & wearables: physics in brief

Bio & wearables has 4 classes on or near the body: ECG / biopotential, PPG / SpO2 / skin temperature, EMG / EEG, and the smart glasses / phone sensor bundle. They differ from room sensing because the sensor touches the subject: coupling to skin, not a radiating aperture, decides what is measured. The bundle is a device, not a physics, and is split into its component classes.

  • Flux and conjugate pair: Biopotentials: V·I, where ion currents in tissue are transduced to electron current at the electrode; PPG: photon flux through tissue, absorbed by haemoglobin (Beer–Lambert).
  • Characteristic scale: Skin–electrode impedance kΩ–MΩ; ECG band ~0.05–150 Hz; EMG ~20–500 Hz up to ~mV, EEG ~0.5–100 Hz at ~µV; PPG at 525–560, 660 and 940 nm with a pulsatile part ~1 % of DC (typ.).
  • Resonance / aperture condition: High input impedance (≥ 100 MΩ) and CMRR (> 100 dB, typ.) with a driven right leg make the electrode a quasi-static “antenna”; for PPG the LED–photodiode spacing sets penetration depth.

In the shared space: the hypothesis is that the device bundle is a natural place to test map fitting, since its parts see the same subject at the same moment; the shared clock, battery and mount are also common causes that can fake agreement. Not measured.

Impedance analogies: one series loop drawn four ways Four panels show the same series loop with a source, a resistance, an inertance and a capacitance. Electrical: V, R, L, C, current I. Acoustic: pressure p, acoustic resistance, acoustic mass (like inductance), compliance (like capacitance), volume velocity U (like current). Mechanical, impedance analogy: force F like voltage, velocity v like current, mass like inductance, compliance 1/k like capacitance, damping like resistance. Thermal: temperature difference like voltage, heat flow like current, thermal resistance and heat capacity only, no inductance, so it is diffusive and never resonates. Dots on the bottom wire show the flow: oscillating in the first three, decaying one way in the thermal loop. Electrical Z = R + jωL + 1/(jωC) V R L C I (current) effort: voltage V flow: current I inertance: inductance L storage: capacitance C loss: resistance R resonance ω0 = 1/√(LC) Acoustic (impedance analogy) Za = p/U (Pa·s/m³); p·U in W p Ra Ma Ca U (volume velocity) pressure p ↔ voltage V volume velocity U ↔ current I acoustic mass Ma ↔ inductance L compliance Ca ↔ capacitance C acoustic resistance Ra ↔ R ω0 = 1/√(MaCa) (Helmholtz) Mechanical (impedance analogy) Zm = F/v (N·s/m); F·v in W F Rm m 1/k v (velocity) force F ↔ voltage V velocity v ↔ current I mass m ↔ inductance L compliance 1/k ↔ capacitance C damping Rm ↔ R ω0 = √(k/m) Thermal diffusive: RC only, no resonance ΔT Rth (no inductor) Cth q (heat flow, W) temperature ΔT ↔ voltage V heat flow q ↔ current I heat capacity Cth ↔ C thermal resistance Rth ↔ R no thermal inductance: τ = Rth·Cth, decays, never rings
The same lumped network in four domains (impedance analogy).

Front-end circuits for this family

Bio & wearables: requirements grid (4 classes)

4 classes in this family. Use the views to move between timing, compute, link, health, physics, scale and governance columns.

Overview

ClassFamily / bandRateBandwidthLink tierMaturityProvenance
ECG / biopotentialBio & wearables250-1000 Hz0.5-4 kB/sMCU busprototypedresearch
PPG / SpO2 / skin tempBio & wearables (also EM: IR)25-500 Hz; commercial wearables sample about 64-68 Hz (signal content 0.5-5 Hz)<2 kB/sWirelesspossibleresearch
EMG / EEGBio & wearablesEEG 100-1000 Hz; EMG up to several kHz (x ch)5-200 kB/sWirelesspossibleresearch
Smart glasses / phone sensor bundleBio & wearablesmixed10 kB/s-5 MB/sWirelessidentifiedrepo

Timing & bandwidth

ClassFamily / bandExamplesRateBandwidthTierLatencyJitterSync
ECG / biopotentialBio & wearablesSEN0213 AD8232 + ADS1115 (cog)250-1000 Hz0.5-4 kB/sT1 10 B-10 kB/ssmsms
PPG / SpO2 / skin tempBio & wearables (also EM: IR)none yet25-500 Hz; commercial wearables sample about 64-68 Hz (signal content 0.5-5 Hz)<2 kB/sT1 10 B-10 kB/ssmsms
EMG / EEGBio & wearablesnone yetEEG 100-1000 Hz; EMG up to several kHz (x ch)5-200 kB/sT2 10 kB-1 MB/s10-100 msmsms
Smart glasses / phone sensor bundleBio & wearablesMentra glasses (phone-parent-node plan)mixed10 kB/s-5 MB/sT2 10 kB-1 MB/s100 msmsms

Compute & storage

ClassComputeCan run onMemoryStoragePower
ECG / biopotentialQRS detectMCUKBrates longmW
PPG / SpO2 / skin templightMCU, phoneKBlongmW
EMG / EEGMLMCU, NPUMBssessionsmW
Smart glasses / phone sensor bundlephone + edgephone, Mac, cloudMBstranscriptsbattery

Link & mesh

ClassTransportLink tierReachUnitMesh status
ECG / biopotentialI2C ADC, BLEMCU busreachable nowsourcecog exists
PPG / SpO2 / skin tempBLEWirelessreachable nowsourcenothing yet
EMG / EEGBLE, USBWirelessneeds new linksourcenothing yet
Smart glasses / phone sensor bundleBLE, Wi-FiWirelessreachable nowsource+processornothing yet

Physics & health

ClassEnv. sensitivityCalibrationFailure signatureCross-checkCommon causeEM-acoustic crossover
ECG / biopotentialelectrode contactnonelead-off, mains hum60 GHz vitals, PPGwearerphonocardiography partner ac1; radar vitals ra3
PPG / SpO2 / skin tempmotionper usermotion artifactradar vitals, ECGwearernone identified
EMG / EEGelectrodeper sessionimpedanceradar silent speechwearernone identified
Smart glasses / phone sensor bundlewearer motionnonecapture stops in backgroundroom sensorsphonenone identified

Physics & flux

Per-class physics annotation. Flux and conjugate pair fix the basis of the representation (rotation); impedance and wave speed fix the global scale; the resonance or aperture condition fixes phase so that only real propagating flux enters a shared space. The shared-space hook is an interpretation to test, not a measured result. Values are order-of-magnitude (~ marks approximations).

ClassPhysics groupConjugate pair / energy fluxCharacteristic scaleResonance / aperture ("antenna") conditionShared-space hook (rotation, scale, phase gate)
ECG / biopotentialELE Electrical power and biopotentialelectrode potential V (ion flux transduced to electron flow V·I); µV–mVskin–electrode impedance kΩ–MΩ; bandwidth 0.05–150 Hz; input impedance ~10 MΩ–GΩ (higher for dry electrodes, typ.)high input Z and CMRR (> 100 dB, typ.) with a driven right leg; the electrode is a quasi-static "antenna"R: V/I pair (voltage and current axes). s: impedance. Phase gate: anti-alias filter and CMRR keep real signal separate from pickup.
PPG / SpO2 / skin tempOPT Optical / infrared photonsphoton flux through tissue; absorption by haemoglobin (Beer–Lambert)green 525–560 nm, red 660 nm, IR 940 nm; pulsatile AC ~1 % of DC (typ.)LED–photodiode spacing sets penetration depth; skin contact pressure; ambient-light rejectionR: polarisation and image-plane axes. s: Z0/n and photon energy hc/λ. Phase gate: coherence or a lock-in reference; ordinary cameras discard phase.
EMG / EEGELE Electrical power and biopotentialelectrode potential V; EMG up to ~mV at 20–500 Hz, EEG ~µV at 0.5–100 Hzelectrode impedance kΩ–100s kΩ; input noise ~1 µV rms (typ.)high Z input, CMRR, shielding; electrode placement sets the sensed volumeR: V/I pair (voltage and current axes). s: impedance. Phase gate: anti-alias filter and CMRR keep real signal separate from pickup.
Smart glasses / phone sensor bundleMIX Composite or multi-physicsbundle of camera, mic, IMU and other physics in one devicesee the component classeshandled per component; the bundle shares a clock, battery and mount (common causes)Split into its component modalities before mapping; each part uses its own group.

Scale

ClassRoom x10Building x300Factory x5000Compute at factoryScale note
ECG / biopotential20 kB/s599 kB/s10 MB/sedge aggregator per floorsame as building
PPG / SpO2 / skin temp10 kB/s300 kB/s5 MB/sedge aggregator per floorsame as building
EMG / EEG316 kB/s9.5 MB/s158 MB/szone edge aggregators; ship derived onlysame as building
Smart glasses / phone sensor bundle3.2 MB/s95 MB/s1.6 GB/sreduce at node; fiber backbone + dedicated computesame as building

Governance

ClassMaturityPrivacyProvenance
ECG / biopotentialprototypedhighproject notes: module types note biopotential; cogs-sen0213; research C §4.5: wearable biosignal review PMC8587479 [E] (ECG 100-1000 Hz, 1 kHz covers most uses)
PPG / SpO2 / skin temppossiblehighresearch C §4.5: wearable biosignal review PMC8587479 [E]; Pixel Watch PPG dataset, arXiv 2512.03988 [E] (about 68 Hz); rest typical
EMG / EEGpossiblehighproject notes: silent speech radar note s3 (comparison); research C §4.5: PMC8587479 [E] (EEG 100-1000 Hz, EMG up to several kHz; sources disagree); rest typical
Smart glasses / phone sensor bundleidentifiedhighproject notes: the phone parent node note